MT2834ZPX Owner's Manual

COMMAND:

Xn

VALUES:

n = 0, 1, 2, 3 or 4

DEFAULT:

X0

DESCRIPTION:

 

 

X0 selects Basic Result Codes (w/o CONNECT 1200,

 

CONNECT 2400).

 

X1 selects Extended Result Codes (w/CONNECT 1200,

 

CONNECT 2400).

 

X2 selects Standard AT Command set with NO DIAL

 

TONE.

 

X3 selects Standard AT Command set with BUSY.

 

X4 selects Standard AT Command set with NO DIAL

 

TONE and BUSY.

COMMAND:

#Xn

VALUES:

n = 0 or 1

DEFAULT:

#X0

DESCRIPTION:

 

 

#X0 selects single XOFF character sent until XON level

 

returns.

 

#X1 selects multiple XOFF characters after buffer level is

 

full.

COMMAND:

Yn

VALUES:

n = 0 or 1

DEFAULT:

Y0

DESCRIPTION:

 

 

Y0 disables sending or responding to long space “break”.

 

Y1 enables sending or responding to long space “breaks”.

COMMAND:

Z

VALUES:

n/a

DEFAULT:

n/a

DESCRIPTION:

 

 

All configuration parameters are reset to default values.

COMMAND:

, (Comma)

VALUES:

n/a

DEFAULT:

n/a

DESCRIPTION:

 

 

Causes pause during dialing.

36

Page 36
Image 36