Chapter 4 - AT Commands,
COMMAND: %DFn
VALUES: n = 0 or 1
DEFAULT: %DF0
DESCRIPTION:
%DF0 selects V.34 Line Probe Data in Graph Format. %DF1 selects V.34 Line Probe Data in Table Format.
COMMAND: %DPn
VALUES: n = 0 or 1
DEFAULT: %DP0
DESCRIPTION:
%DP0 selects not to read Line Probe Information from DSP during handshaking.
%DP1 selects read Line Probe Information from DSP during handshaking.
COMMAND: >DTn
VALUES: n = 0 or 1
DEFAULT: >DT0
DESCRIPTION:
>DT0 disables modem detecting DTMF tones.
>DT1 enables modem detecting and reporting DTMF tones when it is
COMMAND: En
VALUES: n = 0 or 1
DEFAULT: E1
DESCRIPTION:
E0 selects do not echo Command mode characters.
E1 selects echo Command mode characters.
COMMAND: $EBn
VALUES: n = 0 or 1
DEFAULT: $EB0
DESCRIPTION:
$EB0 selects 10 bit mode. $EB1 selects 11 bit mode.
COMMAND: | &En |
|
VALUES: | n = 0 thru 15 |
|
DEFAULT: | &E1, &E4, &E6, &E10, &E13, &E15 | |
DESCRIPTION: |
|
|
| &E0 selects no error correction. | |
| &E1 selects V.42 | |
| &E2 selects V.42 | Reliable Mode. |
27