MultiModemUSB User Guide

Command:

&Gn

V.22bis Guard Tone Control

Values:

 

n = 0, 1, or 2

Default:

 

0

Description:

&G0

Disable guard tone.

 

&G1

Set guard tone to 550 Hz.

 

&G2

Set guard tone to 1800 Hz.

Note: The &G command is not used in North America.

Command:

&Jn

Auxiliary Relay Control

Values:

 

n = 0

Default:

 

0

Description:

&J0

The auxiliary relay is never closed.

 

&J1

Not supported—responds ERROR.

Command:

&Kn

Flow Control Selection

Values:

 

n = 0, 3, or 4

Defaults:

 

3

Description:

&K0

Disable flow control.

 

&K3

Enable CTS/RTS hardware flow control.

 

&K4

Enable XON/XOFF software flow control.

Command:

&Mn

Communications Mode

Values:

 

n = 0

Defaults:

 

0

Description:

&M0

Asynchronous mode.

 

&M1

Not supported—responds ERROR.

Command:

&Qn

Asynchronous Communications Mode

Values:

 

n = 0, 5, 6, 8, or 9

Default:

 

5

Description:

&Q0

Asynchronous with data buffering. Same as \N0.

 

&Q5

Error control with data buffering. Same as \N3.

 

&Q6

Asynchronous with data buffering. Same as \N0.

 

&Q8

MNP error control mode. If MNP error control is not established, the modem falls back according

 

 

to the setting in S36.

 

&Q9

V.42 or MNP error control mode. If neither error control is established, the modem falls back

 

 

according to the setting in S36.

Command:

&Sn

Data Set Ready (DSR) Control

Values:

 

n = 0 or 1

Default:

 

0

Description:

&S0

Force DSR always high (on).

 

&S1

Let DSR go high only during a connection.

Command:

&Tn

V.54 Test Commands

Values:

 

n = 0, 1, 3 or 6

Default:

 

None

Description:

&T0

Abort. Stop any test in progress.

 

&T1

Local analog loopback test.

 

&T3

Local digital loopback test.

 

&T6

Remote digital loopback test.

Note: To stop a test, you must use the escape sequence (+++AT) before typing AT&T0.

Command:

&V

Display Current Settings

Values:

 

n/a

Description:

 

Displays the active modem settings, including the callback security settings if callback security is

 

 

enabled. If the setup password has been entered, it also displays the callback security passwords.

44