Multiquip DA7000WGH, DA700SSW Operation, Before Starting the Engine, Fuel Cock Lever ON, Correct

Models: DA700SSW DA7000WGH

1 172
Download 172 pages 43.7 Kb
Page 28
Image 28
OPERATION

OPERATION

Before Starting the Engine

CAUTION

The engine’s exhaust contains harmful emissions.

ALWAYS have adequate ventilation when operating. Direct exhaust away from nearby personnel.

Before Starting the Engine WARNING

NEVER manually start the engine with the main or GFCI circuit breakers in the ON (closed) position.

1.Open the cabinet door and turn the fuel cock lever (Figure 14) to the “ON” position.

Figure 14. Fuel Cock Lever (ON)

2.NEVER operate the generator with the doors open (Figure 15). Operation with the doors open may cause insufficient cooling of the unit, and engine damage may result. Close the doors for normal operation.

3.NEVER start the engine with the main circuit breaker in the ON position.Always place circuit breaker (Figure 16) in the OFF position before starting.

OFF

 

OFF

 

 

 

 

 

 

 

 

 

25A

 

25A

 

 

 

Figure 16. Main Circuit Breaker (OFF)

4.NEVER start the engine with the GFCI circuit breaker in the ON position. Always place circuit breaker (Figure 17) in the OFF position before starting the engine.

Figure 17. GFCI Circuit Breaker (OFF)

Starting the Engine

1.Insert the key into the starter switch (Figure 18) and turn it to the “RUN” position. Check to see that the oil pressure and charge Lights on the "Warning Lamp Unit Display " are lit. If either light is not lit, check the system and wiring (refer to the Engine Operation Manual).

Figure 14. Fuel Cock Lever (ON)WHISPERWATT 7KW AC Model DA-7000SS

Figure 16. Main Circuit Breaker (OFF)Figure 17. GFCI Circuit Breaker (OFF)00000Starting the Engine

120/240V CORRECT Figure 15. Generator DoorsFigure 18. Starter SwitchManual background 120/240V

Manual backgroundWHISPERWATT 7KW AC Model DA-7000SS

00000

ATT

7000

 

 

 

WHISPERW

 

120/240V

 

 

120/240V

 

 

CORRECT Manual background

Figure 15. Generator Doors

Figure 18. Starter Switch

2.Turn the ignition key to the HEAT position. When the preheat light goes off, turn the key to the START position to start the engine. As soon as the engine starts, release the key. The key will automatically return to the RUN position.

3.During winter or when the surrounding air temperature is cold, in situations where a load start is required, turn the key to the HEAT position, you must wait until the preheat light goes off.

PAGE 28 — DA7000 SERIES GENERATORS• OPERATION AND PARTS MANUAL — REV. #5 (01/20/11)