TRAILER GUIDELINES

Wheel Rims

If the trailer has been struck, or impacted, on or near the wheels, or if the trailer has struck a curb, inspect the rims for damage (i.e. being out of round); and replace any damaged wheel. Inspect the wheels for damage every year, even if no obvious impact has occurred.

Wheels, Bearings and Lug Nuts

A loose, worn or damaged wheel bearing is the most common cause of brakes that grab.

To check wheel bearings, jack trailer and check wheels for side-to-side looseness. If the wheels are loose, or spin with a wobble, the bearings must be serviced or replaced. Check inflation pressure weekly during use to insure the maximum tire life and tread wear. Most trailer axles are built with sealed bearings that are not serviceable. Sealed bearings must be replaced as complete units.

WARNING

Lug nuts are prone to loosen after initial installation, which can lead to death or serious injury. Check all wheel lug nuts periodically.

Lug Nut Torque Requirements

It is extremely important to apply and maintain proper wheel mounting torque on the trailer. Be sure to use only the fasteners matched to the cone angle of the wheel. Proper procedure for attachment of the wheels is as follows:

1.Start all wheel lug nuts by hand.

2.Torque all lug nuts in sequence. See Figure K. DO NOT torque the wheel lug nuts all the way down. Tighten each lug nut in 3 separate passes as defined by Table C.

NOTICE

NEVER use an pneumatic air gun to tighten wheel lug nuts.

Over-tightening lug nuts will result in breaking the studs or permanently deforming the mounting stud holes in the wheels.

3.Check to see if the lug nuts are tight after the first 10, 25 and 50 miles of driving and before each tow thereafter

Figure K. Wheel Lug Nuts Tightening Sequence

Table C. Tire Torque Requirements

Wheel Size

First Pass

Second Pass

Third Pass

FT-LBS

FT-LBS

FT-LBS

 

 

 

 

 

12"

20-25

35-40

50-65

 

 

 

 

13"

20-25

35-40

50-65

 

 

 

 

14"

20-25

50-60

90-120

15"

20-25

50-60

90-120

16"

20-25

50-60

90-120

Lights and Signals

Before each tow, check the trailer taillights, stoplights, turn signals and any clearance lights for proper operation.

Replace any broken or burned-out lamps as necessary. Check the wire harness for cuts, fraying or other damage. If it needs replacing, contact your dealer.

WARNING

Improper operating taillights, stoplights and turn signals can cause collisions.

Check all lights before each tow.

DA7000 SERIES GENERATORS • OPERATION AND PARTS MANUAL — REV. #5 (01/20/11) — PAGE 51

Page 51
Image 51
Multiquip DA700SSW, DA7000WGH Wheel Rims, Wheels, Bearings and Lug Nuts, Lug Nut Torque Requirements, Lights and Signals

DA700SSW, DA7000WGH specifications

The Multiquip DA7000WGH and DA700SSW are exceptional diesel-powered generators designed to deliver reliable power across a variety of demanding applications. Known for their durability and efficiency, these generators are ideal for construction sites, events, and backup power needs.

The DA7000WGH model features a robust 7000-watt output, making it suitable for heavy-duty tasks. It is powered by a water-cooled, four-cylinder diesel engine, which not only ensures longer operational life but also minimizes noise levels during use. The generator is equipped with a heavy-duty steel frame that provides superior protection against the rigors of job site environments. Additionally, its compact design allows for easy transport and maneuverability, making it a practical choice for contractors and event organizers alike.

In terms of technology, the DA7000WGH includes advanced digital instrumentation. An intuitive control panel offers easy access to critical information such as voltage, frequency, and operating hours. This feature allows users to monitor the generator's performance effectively, ensuring optimal operation and preemptive maintenance. Moreover, the generator boasts an integrated fuel gauge and an automatic low oil shut-off feature that enhances both safety and longevity.

On the other hand, the DA700SSW model presents an equally impressive set of features tailored for those requiring a quieter operation. Utilizing a sound-attenuated enclosure, it significantly reduces noise levels without sacrificing power output. This makes the DA700SSW an excellent choice for outdoor events, festivals, and applications where noise restrictions may apply.

Both models incorporate a heavy-duty alternator designed to provide clean and stable power, critical for sensitive electronics. The generators are also equipped with multiple output options, including 120V and 240V outlets, ensuring versatility for a range of equipment and tools.

In conclusion, the Multiquip DA7000WGH and DA700SSW generators stand out for their combination of power, durability, and advanced technology. Whether you require a rugged workhorse for a construction project or a quieter model for an outdoor event, these generators deliver reliable performance tailored to meet various demands. With their advanced features and easy transportability, they represent a smart investment for anyone in need of dependable power solutions.