MAINTENANCE

Maintenance

Perform the scheduled maintenance procedures as defined by Table 8 and below:

Engine Oil

Every 100 hours: Change engine oil after the first 50 hours of operation and 100 hours thereafter. Always check the crankcase oil level prior to each use, or when the fuel tank is filled. Insufficient oil may cause severe engine damage. Make sure generator is level when checking oil level. The oil level must be between the two notches on the dipstick as shown in Figure 8.

1.Remove engine oil drain plug located at the bottom of the generator enclosure (Figure 29) and drain oil from crankcase.For best results drain oil while engine is warm. Reinstall oil drain plug, and add engine oil as specified in Table 5. Crankcase oil capacity is 2.64 qts. (2.5 liters).

2.Screw on new oil filter by hand until seal contacts the fi lter mounting base. Install drain bolt with sealing washer and hand tighten.

NOTICE

When installing the oil filter, coat rubber seal with a small amount of lubricant (motor oil). DO NOT over- tighten cartridge. Hand tighten only.

3.Replace engine oil with recommended type oil as listed in Table 5. For engine oil capacity, see Table 2 (engine specifications). Fill to upper limit as shown in Figure 8.

Engine Air Cleaner

Every 50 hours: The air cleaner employed on the KUBOTA Z482 series engines is a dry type, NEVER apply oil to it. If generator is used in severe dusty areas service air cleaner element more frequently.

1.Release the air cleaner retaining clamps (Figure 31) and remove the air cleaner element.

Figure 29. Engine Oil Drain Plug

Oil Filter Cartridge

Every 200 hours: Replace the engine oil filter cartridge after every 200 hours of operation.

1.Clean oil filter mounting base, and coat oil filter seal (Figure 30) with clean engine oil.

Figure 30. Oil Filter Cartridge

Figure 31. Air Cleaner

2.Wipe the inside of the air cleaner with a clamp cloth and remove all dust and debris that may have accumulated inside air cleaner body.

3.Tap the edge of element lightly to allow heavy dust build-up to fall off.

4.Tap the paper filter element (Figure 31) several times on a hard surface to remove dirt, or blow compressed air [not exceeding 99 psi (686 kPa, 2.1 kgf/cm2)] through the filter element from from the inside while turning the element. NEVER brush off dirt. Brushing will force dirt into the fibers.

5.Replace the filter element once a year or every six cleanings or if it is excessively dirty

DA7000 SERIES GENERATORS • OPERATION AND PARTS MANUAL — REV. #5 (01/20/11) — PAGE 33

Page 33
Image 33
Multiquip DA700SSW, DA7000WGH manual Maintenance, Engine Oil, Engine Air Cleaner, Oil Filter Cartridge

DA700SSW, DA7000WGH specifications

The Multiquip DA7000WGH and DA700SSW are exceptional diesel-powered generators designed to deliver reliable power across a variety of demanding applications. Known for their durability and efficiency, these generators are ideal for construction sites, events, and backup power needs.

The DA7000WGH model features a robust 7000-watt output, making it suitable for heavy-duty tasks. It is powered by a water-cooled, four-cylinder diesel engine, which not only ensures longer operational life but also minimizes noise levels during use. The generator is equipped with a heavy-duty steel frame that provides superior protection against the rigors of job site environments. Additionally, its compact design allows for easy transport and maneuverability, making it a practical choice for contractors and event organizers alike.

In terms of technology, the DA7000WGH includes advanced digital instrumentation. An intuitive control panel offers easy access to critical information such as voltage, frequency, and operating hours. This feature allows users to monitor the generator's performance effectively, ensuring optimal operation and preemptive maintenance. Moreover, the generator boasts an integrated fuel gauge and an automatic low oil shut-off feature that enhances both safety and longevity.

On the other hand, the DA700SSW model presents an equally impressive set of features tailored for those requiring a quieter operation. Utilizing a sound-attenuated enclosure, it significantly reduces noise levels without sacrificing power output. This makes the DA700SSW an excellent choice for outdoor events, festivals, and applications where noise restrictions may apply.

Both models incorporate a heavy-duty alternator designed to provide clean and stable power, critical for sensitive electronics. The generators are also equipped with multiple output options, including 120V and 240V outlets, ensuring versatility for a range of equipment and tools.

In conclusion, the Multiquip DA7000WGH and DA700SSW generators stand out for their combination of power, durability, and advanced technology. Whether you require a rugged workhorse for a construction project or a quieter model for an outdoor event, these generators deliver reliable performance tailored to meet various demands. With their advanced features and easy transportability, they represent a smart investment for anyone in need of dependable power solutions.