inspection/setup

MAIN CIRCUIT BREAKER

The generator is equipped with a 3-pole, 600-amp circuit breaker to protect the camlok receptacles from overload. Make sure that the main circuit breaker is in the OFF position prior to starting the engine.

Lubrication Oil

Fill the engine crankcase with lubricating oil through the filler hole, but DO NOT overfill. Make sure the generator is level and verify that the oil level is maintained between the two notches (Figure 11) on the dipstick. See Table 11 for proper selection of engine oil.

Figure 11. Engine Oil Dipstick

When checking the engine oil, be sure to check if the oil is clean. If the oil is not clean, drain the oil by removing the oil drain plug, and refill with the specified amount of oil as outlined in the Cummins Engine Owner’s Manual. Oil should be warm before draining.

Other types of motor oils may be substituted if they meet the following requirements:

„„ API Service Classification CC/SC

„„API Service Classification CC/SD

„„API Service Classification CC/SE

„„API Service Classification CC/SF

Table 11. Recommended Motor Oil

Fuel Check

DANGER

Fuel spillage on a hot engine can cause a fire or explosion. If fuel spillage occurs, wipe up the spilled fuel completely to prevent fire hazards. NEVER smoke around or near the generator.

Refilling the Fuel System

CAUTION

ONLY properly trained personnel who have read and understood this section should refill the fuel tank system.

This generator has a fuel tank located in the sub base assembly frame. ALWAYS fill the fuel tank with clean fresh #2 diesel fuel. DO NOT fill the fuel tank beyond its capacity.

Pay attention to the fuel tank capacity when replenishing fuel. The fuel tank cap must be closed tightly after filling. Handle fuel in a safe container. If the container does not have a spout, use a funnel. Wipe up any spilled fuel immediately.

Refueling Procedure:

WARNING

Diesel fuel and its vapors are dangerous to your health and the surrounding environment. Avoid skin contact and/or inhaling fumes.

CAUTION

ALWAYS make sure generator is on firm level ground before refueling to prevent spilling and maximize the amount of fuel that can be pumped into the tank.

page 30 — SG1400C3 Studio Generator • operation and parts manual — rev. #1 (02/15/12)

Page 30
Image 30
Multiquip SG1400C3-55748 Inspection/setup, Lubrication Oil, Fuel Check, Refilling the Fuel System, Refueling Procedure

SG1400C3-55748 specifications

The Multiquip SG1400C3-55748 is an advanced generator designed for a wide array of applications, including construction sites, event management, and emergency power backup. At the heart of this robust unit lies a powerful engine that produces reliable energy output, ensuring that it meets the demands of both professionals and casual users alike.

The SG1400C3-55748 boasts an impressive power rating of 14 kW, making it suitable for powering multiple tools and equipment simultaneously. This generator is equipped with a durable and fuel-efficient engine, capable of running for extended periods without compromising performance. Efficient fuel consumption is a critical feature, allowing users to maximize productivity while minimizing operational costs.

One of the standout features of the SG1400C3-55748 is its advanced sound attenuation system. This generator is designed with a noise-reduced enclosure that significantly lowers operational sound levels, making it an excellent choice for noise-sensitive environments. This feature not only enhances user comfort but also complies with noise regulations that may be in effect at various job sites.

The Multiquip SG1400C3-55748 incorporates advanced technologies, including automatic voltage regulation (AVR), which offers stable power output and protects connected devices from voltage fluctuations. This is particularly beneficial for sensitive electronics and equipment that could be damaged by irregular power supply. The generator also features an easy-to-read control panel that allows users to monitor output levels and operating conditions effortlessly.

Safety is a priority for the SG1400C3-55748, featuring multiple safety mechanisms such as low oil shutdown and over-temperature protection. These features ensure that the generator operates within safe parameters, reducing the risk of damage to the unit and connected loads.

The portability of the Multiquip SG1400C3-55748 is enhanced by its compact design and integrated wheel kit, allowing easy transportation between job sites. Whether for emergency use, outdoor events, or construction, this generator offers the versatility and reliability needed for various applications.

In summary, the Multiquip SG1400C3-55748 is a powerful, efficient, and portable generator. Its advanced technologies, user-friendly features, and safety mechanisms make it an ideal choice for professionals and homeowners alike, ensuring that you have the reliable power you need when you need it most.