troubleshooting (engine)

Troubleshooting (Engine)

Symptom

Possible Problem

Solution

 

 

 

 

No Fuel reaching injection pump?

Add fuel. Check entire fuel system.

 

 

 

 

Defective fuel pump?

Replace fuel pump.

 

 

 

 

Fuel filter clogged?

Replace fuel filter and clean tank.

 

 

 

 

Faulty fuel supply line?

Replace or repair fuel line.

 

 

 

 

Compression too low?

Check piston, cylinder and valves. Adjust or

 

repair per engine repair manual.

Engine will not start or start is delayed,

 

Fuel pump not working correctly?

Repair or replace fuel pump.

although engine can be turned over.

Oil pressure too low?

Check engine oil pressure.

 

 

Low starting temperature limit exceeded?

Comply with cold starting instructions and

 

proper oil viscosity.

 

 

 

 

 

 

Defective battery?

Charge or replace battery.

 

 

 

 

Air or water mixed in fuel system?

Check carefully for loosened fuel line

 

coupling, loose cap nut, etc.

 

 

 

 

 

 

Engine oil too thick?

Refill engine crankcase with correct type of

At low temperatures engine will not start.

oil for winter environment.

 

 

Defective battery?

Replace battery.

 

 

 

Engine fires but stops soon as starter is

Fuel filter blocked?

Replace fuel filter.

 

 

Fuel supply blocked?

Check the entire fuel system.

switched off.

 

 

Defective fuel pump?

Replace fuel pump.

 

 

 

 

 

Fuel tank empty?

Add fuel.

 

 

 

Engine stops by itself during normal

Fuel filter blocked?

Replace fuel filter.

 

 

Defective fuel pump?

Replace fuel pump.

operation.

 

 

 

Mechanical oil pressure shutdown sensor

Add oil. Replace low oil shutdown sensor if

 

stops the engine due to low oil?

necessary.

 

Fuel tank empty?

Replace fuel filter.

 

Fuel filter clogged?

Replace fuel filter.

 

Fuel tank venting is inadequate?

Ensure that tank is adequately vented.

 

Leaks at pipe unions?

Check threaded pipe unions tape and tighten

 

unions a required.

 

 

Low engine power, output and speed.

 

 

Speed control lever does not remain in

See engine manual for corrective action.

 

 

selected position?

 

 

 

 

 

 

Engine oil level too full?

Correct engine oil level.

 

 

 

 

 

Use No. 2-D diesel fuel only. Check the fuel

 

Injection pump wear?

injection pump element and delivery valve

 

 

assembly and replace as necessary.

SG1400c3 studio generator • operation and parts manual — rev. #1 (02/15/12) — page 45

Page 45
Image 45
Multiquip SG1400C3-55748 manual Troubleshooting engine, Troubleshooting Engine

SG1400C3-55748 specifications

The Multiquip SG1400C3-55748 is an advanced generator designed for a wide array of applications, including construction sites, event management, and emergency power backup. At the heart of this robust unit lies a powerful engine that produces reliable energy output, ensuring that it meets the demands of both professionals and casual users alike.

The SG1400C3-55748 boasts an impressive power rating of 14 kW, making it suitable for powering multiple tools and equipment simultaneously. This generator is equipped with a durable and fuel-efficient engine, capable of running for extended periods without compromising performance. Efficient fuel consumption is a critical feature, allowing users to maximize productivity while minimizing operational costs.

One of the standout features of the SG1400C3-55748 is its advanced sound attenuation system. This generator is designed with a noise-reduced enclosure that significantly lowers operational sound levels, making it an excellent choice for noise-sensitive environments. This feature not only enhances user comfort but also complies with noise regulations that may be in effect at various job sites.

The Multiquip SG1400C3-55748 incorporates advanced technologies, including automatic voltage regulation (AVR), which offers stable power output and protects connected devices from voltage fluctuations. This is particularly beneficial for sensitive electronics and equipment that could be damaged by irregular power supply. The generator also features an easy-to-read control panel that allows users to monitor output levels and operating conditions effortlessly.

Safety is a priority for the SG1400C3-55748, featuring multiple safety mechanisms such as low oil shutdown and over-temperature protection. These features ensure that the generator operates within safe parameters, reducing the risk of damage to the unit and connected loads.

The portability of the Multiquip SG1400C3-55748 is enhanced by its compact design and integrated wheel kit, allowing easy transportation between job sites. Whether for emergency use, outdoor events, or construction, this generator offers the versatility and reliability needed for various applications.

In summary, the Multiquip SG1400C3-55748 is a powerful, efficient, and portable generator. Its advanced technologies, user-friendly features, and safety mechanisms make it an ideal choice for professionals and homeowners alike, ensuring that you have the reliable power you need when you need it most.