startup

9.If paralleling to another unit and the bus was already energized from another unit (BUS HOT light already on), pressing to close GCB button once would initiate a synchronizing mode. The light above the button will begin flashing, bring the generator into phase and automatically close the breaker. Once the breaker closes, the light above the button would then become solid and the generators would now be in parallel. As load is applied, units will share the load proportionally.

CLOSING THE ENCLOSURE DOORs

1.Close the enclosure doors once the generator has started (Figure 29). Top vents stay open for proper ventilation.

RAIN DOOR

INTAKE VENT

Close

Doors

Figure 29. Engine Enclosure Doors

2.If access to the controls or other components is necessary while the engine is running, make sure the doors are not left open for an extended period of time.

3.To protect the unit from rain, the top intake vent can be closed by opening the upper front vent door on the generator enclosure. The front vent will automatically close the upper roof intake vent. The upper exhaust vent will remain open.

Normal Shutdown Procedure

To shutdown the generator, use the following procedure:

WARNING

NEVER stop the engine suddenly except in an emergency.

1.Press the GCB control button on the controller (Figure 30) to open circuit breaker.

Open GCB

PRESS BUTTON

Figure 30. Generator Circuit Breaker (Open)

2.Let the engine cool by running it at full speed for 3-5 minutes with no load applied.

3.Press the STOP button (Figure 31) on the controller. The engine will go to idle mode.

Figure 31. STOP Button

4. Press the STOP button again to shut down the engine.

NOTICE

If STOP button is not pressed again, the engine will remain in idle mode for about an hour then will shut down.

5.Place the Control Power switch (Figure 32) on the control panel to the OFF position.

OFF (DOWN)

Figure 32. Control Power Switch (OFF)

emergency Shutdown Procedure

1.Press the STOP button twice (Figure 31) on the controller to shut down the engine.

2.Place the main circuit breaker (Figure 30) in the OFF position.

page 36 — SG1400C3 Studio Generator • operation and parts manual — rev. #1 (02/15/12)

Page 36
Image 36
Multiquip SG1400C3-55748 manual Closing the Enclosure DOORs, Normal Shutdown Procedure, Emergency Shutdown Procedure

SG1400C3-55748 specifications

The Multiquip SG1400C3-55748 is an advanced generator designed for a wide array of applications, including construction sites, event management, and emergency power backup. At the heart of this robust unit lies a powerful engine that produces reliable energy output, ensuring that it meets the demands of both professionals and casual users alike.

The SG1400C3-55748 boasts an impressive power rating of 14 kW, making it suitable for powering multiple tools and equipment simultaneously. This generator is equipped with a durable and fuel-efficient engine, capable of running for extended periods without compromising performance. Efficient fuel consumption is a critical feature, allowing users to maximize productivity while minimizing operational costs.

One of the standout features of the SG1400C3-55748 is its advanced sound attenuation system. This generator is designed with a noise-reduced enclosure that significantly lowers operational sound levels, making it an excellent choice for noise-sensitive environments. This feature not only enhances user comfort but also complies with noise regulations that may be in effect at various job sites.

The Multiquip SG1400C3-55748 incorporates advanced technologies, including automatic voltage regulation (AVR), which offers stable power output and protects connected devices from voltage fluctuations. This is particularly beneficial for sensitive electronics and equipment that could be damaged by irregular power supply. The generator also features an easy-to-read control panel that allows users to monitor output levels and operating conditions effortlessly.

Safety is a priority for the SG1400C3-55748, featuring multiple safety mechanisms such as low oil shutdown and over-temperature protection. These features ensure that the generator operates within safe parameters, reducing the risk of damage to the unit and connected loads.

The portability of the Multiquip SG1400C3-55748 is enhanced by its compact design and integrated wheel kit, allowing easy transportation between job sites. Whether for emergency use, outdoor events, or construction, this generator offers the versatility and reliability needed for various applications.

In summary, the Multiquip SG1400C3-55748 is a powerful, efficient, and portable generator. Its advanced technologies, user-friendly features, and safety mechanisms make it an ideal choice for professionals and homeowners alike, ensuring that you have the reliable power you need when you need it most.