maintenance

Fuel Tank Inspection

In addition to cleaning the fuel tank, the following components should be inspected for wear:

„„Rubber Suspension — look for signs of wear or deformity due to contact with oil. Replace the rubber suspension if necessary.

„„Fuel Hoses — inspect nylon and rubber hoses for signs of wear, deterioration, and hardening.

„„FuelTank Lining — inspect the fuel tank lining for signs of excessive amounts of oil and other foreign matter.

Replacing Fuel Filter

„„Replace the fuel filter cartridge with a new one every 500 hours.

„„Loosen the drain plug at the lower top of the fuel filter. Drain the fuel in the fuel body together with the mixed water. DO NOT spill the fuel during disassembly.

„„Vent any air.

Air Removal

If air enters the fuel injection system of a diesel engine, starting becomes impossible. After running out of fuel, or after disassembling the fuel system, bleed the system. Refer to the Cummins engine manual for details.

Check Oil Level

Check the crankcase oil level prior to each use, or when the fuel tank is filled. Insufficient oil may cause severe damage to the engine. The oil level must be between the two notches on the dipstick.

Replacing Oil Filter

1.Remove the old oil filter.

2.Apply a film of oil to the gasket on the new oil filter.

3.Install the new oil filter.

4.After the oil filter has been replaced, the engine oil will drop slightly. Run the engine for a while and check for leaks before adding more oil if needed. Clean excessive oil from engine.

Flushing Out Radiator and Replacing Coolant

WARNING

Allow engine to cool before flushing out radiator. Flushing the radiator while hot could cause serious burns from water or steam.

1.Remove radiator cap. Remove coolant drain plug located on side of generator. Place coolant drain lever in the open position to drain coolant.

2.Flush the radiator by running clean tap water through radiator until signs of rust and dirt are removed. Do not clean radiator core with any objects, such as a screwdriver.

3.Check hoses for softening and kinks. Check clamps for signs of leakage.

4.Move lever to the closed position and reinstall coolant drain plug.

5.Replace with coolant as recommended by the engine manufacturer.

6.Close radiator cap tightly.

Generator Storage

For long term storage of the generator the following is recommended:

1.Drain the fuel tank completely.Treat with a fuel stabilizer if necessary.

2.Completely drain the oil from the crankcase and refill, if necessary, with fresh oil.

3.Clean the entire generator, inside and outside.

4.Disconnect the battery.

5.Make sure engine coolant is at proper level.

6.Cover the generator and store in a clean, and dry place.

page 40 — SG1400C3 Studio Generator • operation and parts manual — rev. #1 (02/15/12)

Page 40
Image 40
Multiquip SG1400C3-55748 Fuel Tank Inspection, Replacing Fuel Filter, Air Removal, Check Oil Level, Replacing Oil Filter

SG1400C3-55748 specifications

The Multiquip SG1400C3-55748 is an advanced generator designed for a wide array of applications, including construction sites, event management, and emergency power backup. At the heart of this robust unit lies a powerful engine that produces reliable energy output, ensuring that it meets the demands of both professionals and casual users alike.

The SG1400C3-55748 boasts an impressive power rating of 14 kW, making it suitable for powering multiple tools and equipment simultaneously. This generator is equipped with a durable and fuel-efficient engine, capable of running for extended periods without compromising performance. Efficient fuel consumption is a critical feature, allowing users to maximize productivity while minimizing operational costs.

One of the standout features of the SG1400C3-55748 is its advanced sound attenuation system. This generator is designed with a noise-reduced enclosure that significantly lowers operational sound levels, making it an excellent choice for noise-sensitive environments. This feature not only enhances user comfort but also complies with noise regulations that may be in effect at various job sites.

The Multiquip SG1400C3-55748 incorporates advanced technologies, including automatic voltage regulation (AVR), which offers stable power output and protects connected devices from voltage fluctuations. This is particularly beneficial for sensitive electronics and equipment that could be damaged by irregular power supply. The generator also features an easy-to-read control panel that allows users to monitor output levels and operating conditions effortlessly.

Safety is a priority for the SG1400C3-55748, featuring multiple safety mechanisms such as low oil shutdown and over-temperature protection. These features ensure that the generator operates within safe parameters, reducing the risk of damage to the unit and connected loads.

The portability of the Multiquip SG1400C3-55748 is enhanced by its compact design and integrated wheel kit, allowing easy transportation between job sites. Whether for emergency use, outdoor events, or construction, this generator offers the versatility and reliability needed for various applications.

In summary, the Multiquip SG1400C3-55748 is a powerful, efficient, and portable generator. Its advanced technologies, user-friendly features, and safety mechanisms make it an ideal choice for professionals and homeowners alike, ensuring that you have the reliable power you need when you need it most.