APPLYING POWER (Side View)

Unscrew & Remove the DC Voltage Input Plug from the Power Input Header

Install the DC Power Cables into the Plug (observing polarity).

For best results keep the power cable length to a maximum of one (1) meter.

Plug the Voltage Input Plug back into the Power Input Header.

Tightening torque for the terminal block power plug is 0.5 Nm/0.368 Pound Foot.

Verify the Power LED stays ON (GREEN).

Note: Only 1 power supply must be connected to power for minimal operation. For redundant power operation, V1 and V2 inputs must be connected to separate DC Voltage sources. This device will draw current from both sources simultaneously. Use 16-28 gauge wire when connecting to the power supply.

Recommended 24V DC Power Supplies, similar to: N-Tron’s P/N NTPS-24-3:

Input AC 115/230V

Power 72W

Output DC 24-28V

35 mm DIN-Rail Mountable

Output Current 3A @ 24V

Dimensions: 45X75X91 mm

 

2.6A @ 28V

 

 

6/28/2007

page 13 of 145

Page 13
Image 13
N-Tron 7014FX2, 7014TX, 7014FXE2 user manual Applying Power Side View