100 Mb Fiber Transceiver Characteristics

Fiber Length

2km*

 

 

TX Power Min/Max

-19dBm/-14dBm

 

 

RX Sensitivity Max

-32dBm

Wavelength Min/Max

1310nm

 

 

15km**

-15dBm/-7dBm

-29dBm

1310dm

40km**

-5dBm/0dBm

-34dBm

1310dm

80km**

-5dBm/0dBm

-34dBm

1550nm

*Multimode Fiber Optic Cable

**Singlemode Fiber Optic Cable

Gigabit Fiber Transceiver (SFP) Characteristics

Fiber Length

TX Power Min/Max

RX Sensitivity Max

Wavelength

Assumed Fiber Loss

Laser Type

*SX Fiber Optic Cable ** LX Fiber Optic Cable

550m* with

10km**

40km**

50/125 µm

 

 

-9.5dBm/-4dBm

-9.5dBm/-3.5dBm

-2dBm/3dBm

 

 

 

-17dBm

-20dBm

-22dBm

850nm

1310nm

1310nm

 

-0.5 dB/km

-0.35 dB/km

VCSEL

FP

DFB

 

 

 

70km**

0dBm/5dBm

-24dBm

1550nm

-0.25 dB/km

DFB

Regulatory Approvals:

Safety: UL Listed per ANSI/ISA-12.12.01-2000 (US and Canada)

This apparatus is suitable for use in Class I, Div 2, Groups A, B, C, and D, T4

EMI: EN61000-6-4, EN55011 – Class A

FCC Title 47, Part 15, Subpart B - Class A

ICES-003 – Class A

EMS: EN61000-6-2

EN61000-4-2 (ESD)

EN61000-4-3 (RS)

EN61000-4-4 (EFT)

EN61000-4-5 (Surge)

EN61000-4-6 (Conducted Disturbances)

6/28/2007