Chapter4 ConnectingSignals
©NationalInstruments Corporation 4-9 NI6013/6014 User Manual
setting ofthe amplifier. The amplifier output voltage is referenced to the
deviceground. The deviceADC measures this outp ut voltagewhen it
performs A/D conversions.
Connecting Analog Input SignalsThe following sections discuss the use of single-ended and differential
measurements andmake recommendations for measuring both floating
and ground-referenced signal sources.
Figure 4-3 summarizes the recommended input configuration for both
types of signal sources.
Figure4-3. Summary of AI Connections
Input
Input
FloatingSignal Source
(NotConnected to Building Ground) GroundedSignal Source
Differential
(DIFF)
Single-Ended—
Nonreferenced
(NRSE)
Examples
•UngroundedThermocouples
•SignalConditioning with
IsolatedOutputs
•BatteryDevices
Example
•Plug-inInstruments with Nonisolated
Outputs
+
–
+
–
V1
ACH
AISENSE
AIGND
+
–
+
–
V1
ACH(+)
ACH(–)
AIGND
+
–
+
–
V1
ACH(+)
ACH(–)
AIGND
R
Seetext for information on bias resistors.
+
–
+
–
V1
ACH
AISENSE
AIGND
R