Figure 5-40. Format of Serial Operation Mode Register (CSIM) (2/4)
Serial interface operation enable/disable specification bit (W)
Shift register Serial clock IRQCSI SO/SB0 and
operation counter flag SI/SB1 pins
CSIE 0 Shift operation Cleared Held Used only for port 0
disabled
1 Shift operation Count operation Can be set. Used in each mode as well
enabled as for port 0
Signal from address comparator (R)
COINote Condition for being cleared (COI = 0) Condition for being set (COI = 1)
When the data in the slave address When the data in the slave address register
register (SVA) does not match the data (SVA) matches the data in the shift
in the shift register register
Note COI can be read only before serial transfer is started or after serial transfer is completed. An
undefined value may result during transfer.
COI data written by an 8-bit manipulation instruction is ignored.
Wake-up function specification bit (W)
WUP 0 Sets IRQCSI each time serial transfer is completed in each mode.
1 Used in the SBI mode only to set IRQCSI only when an address received after bus release
matches the data in the slave address register (wake-up state). SB0 or SB1 goes to high-
impedance state.
Caution When WUP = 1 is set during BUSY signal output, BUSY is not released. In the SBI mode,
the BUSY signal is output until the next falling edge of the serial clock (SCK) appears after
release of BUSY is directed. Before setting WUP = 1, be sure to confirm that pin SB0 (or
SB1) is high after releasing BUSY.