150
ยต
PD78214 Sub-Series
Fig. 7-53 Capture Operation
Remark Dn: TM1 count value (n = 0, 1, 2, ...)
CLR10 = 0, CLR11 = 0, CM = 1
Count starts
TM1
count value
D0 D1 D2
D2
D1
FFH
0H
INTP0
pin input
INTP0
interrupt request
Capture/compare
register(CR11)
OVF1
D0