Nilfisk-Advance America 5200B Before Machine Start-Up, cWithout batteries, Battery installation

Models: 5200B

1 70
Download 70 pages 33.44 Kb
Page 9
Image 9
c)Without batteries

INSTRUCTIONS FOR USE Battery installation

3.Fill up each battery element with sulfuric acid for batteries (density from 2.80 to 2.84 lb at 77 °F (1.27 to 1.29 Kg at 25°C)) in accordance with the instructions specified in the Battery Instruction Manual.

The correct quantity of sulfuric acid is indicated in the Battery Instruction Manual.

Let the battery rest and fill in with sulfuric acid in accordance with the instructions specified in the Battery Instruction Manual.

4.Charge the battery (see the procedure in the Maintenance chapter).

c)Without batteries

1.Buy appropriate batteries (see the Technical Data paragraph and the installation diagram (15, Fig. V)).

Apply to battery qualified retailers to choose and install the battery.

2.Install and set the machine batteries according to WET or GEL batteries (see the procedure in the following paragraph).

3.Recharge the batteries (see the procedure in the Maintenance chapter).

BATTERY INSTALLATION AND WET OR GEL BATTERY SETTING

Battery installation

1.Install the batteries on the machine according to the diagram (15, Fig. V).

According to the battery dimensions, check if it is possible to put them inside the related plastic container, supplied with the machine.

If the batteries dimensions are larger than the container capacity, use the square guides, supplied with the machine, to ensure the stability inside the battery compartment.

WARNING!

Non-sealed lead/acid batteries always need an appropriate container to prevent the acid form leaking.

Do not install the non-sealed lead/acid batteries without an appropriate container.

WET or GEL battery setting

NOTE

The machine factory setting is for lead (WET) batteries. If this setting corresponds to the type of battery installed on your machine, do not set the batteries.

Otherwise, perform the following operations:

2.It is necessary to set the electronic board of the machine according to the type of batteries installed (WET or GEL). Proceed as follows:

Turn the ignition switch (18, Fig. B) to “0” position;

Open the hood (13, Fig. C) and hold it by using the related rod (16, Fig. V);

Disconnect the battery connector (4, Fig. V);

Remove the screws (1, Fig. AD) and carefully pull out the right control panel (2);

Install a jumper wire (1, Fig. AE) on the WET connectors (2) for lead batteries or on the GEL connectors (3) for gel batteries;

Carefully reassemble the control panel (2, Fig. AD) and fix it by using the related screws (1);

Reconnect the battery connector (4, Fig. V);

Disengage the lock rod (16, Fig. V) and close the hood (13, Fig. C).

BEFORE MACHINE START-UP

1.Check that there are no open doors/hoods and that the machine is in normal operating conditions.

2.If the machine has not been used after being transported, check that all the blocks used for the transportation have been removed.

146 1996 000(2)2004-08Terra™ 5200B