Installation
DRAFT
Copyright Nokia Telecommunications Oy
NTC C33539002SE_A0 4-9
The Nokia M10 command line interface includes a step mode to
automate the process of entering configuration settings. When you use
the Config step mode, the CLI prompts you for all required and
optional information. You can enter the configuration values
appropriate for your site without having to enter complete CLI
commands.
When you are in step mode, the CLI prompts you to enter required and
optional settings. If a setting has a default value or a current setting, the
command line interface displays the default value for the command in
parentheses. If a command has a limited number of acceptable values,
those values are presented in brackets, with each value separated by a
vertical line. For example, the following CLI step command indicates
that the default value is off and that valid entries are limited to on and
off.
option (off) [on|off]: on
You can accept the default value for a field by pressing the Enter key .
To use a different value, type it in and press Enter.
Enter the Config step mode by typing set from the top node of the
Config hierarchy. See Chapter 5 section Stepping through M10
configuration for more information on the step mode.
In the following example the values changed by the user are in bold
type. The default values have been accepted by pressing Enter.
M10> config
Config Mode v1.0
(admin level privileges –– read/write
M10 (top)>>set
Stepping set mode (press Control–X <Return/Enter> to
exit)...
system
name (”M10”): <Enter>
Diagnostic Level List
low
medium
high
warnings
failures
diagnostic-level (high): <Enter>
dmt option (on) [on|off]: <Enter>