Nordyne RL 90+, RC 92+ CAPACITIES -FurnaceAirflow Data, G6RC UPFLOW FURNACE, Can be C or N

Models: RC 92+ RL 90+

1 40
Download 40 pages 28.41 Kb
Page 6
Image 6
G6RC UPFLOW FURNACE

6

G6RC UPFLOW FURNACE

 

Model

Heating

 

 

 

 

 

 

 

External Static Pressure (Inches Water Column)

 

 

 

 

 

 

Number

Input

Motor

Motor

0.1

 

0.2

 

0.3

 

0.4

 

0.5

 

0.6

 

0.7

 

0.8

 

 

*RC-

(Btuh)

Speed

HP

CFM

Rise

CFM

Rise

CFM

Rise

CFM

Rise

CFM

Rise

CFM

Rise

CFM

Rise

CFM

Rise

 

 

 

High*

 

950

36

920

38

890

39

850

41

800

43

750

46

690

50

630

55

 

040( )-08A

40,000

Medium**

1/5

740

47

710

49

680

51

650

53

600

58

550

63

490

-

430

-

 

 

 

Low

 

620

56

590

59

560

62

520

-

470

-

410

-

350

-

290

-

 

 

 

High*

 

1330

-

1280

-

1230

-

1170

-

1120

-

1030

-

940

37

850

41

 

040( )-12A

40,000

Medium**

1/3

1190

-

1160

-

1110

-

1060

-

1010

-

910

38

820

42

720

48

 

 

 

Low

 

830

42

810

43

780

44

760

46

720

48

670

52

610

57

550

63

 

 

 

High*

 

1310

-

1260

-

1210

-

1160

45

1100

47

1040

50

980

53

920

56

 

060( )-12A

60,000

Medium**

1/3

1160

45

1120

46

1080

48

1050

49

990

52

940

55

890

58

830

63

 

 

 

Low

 

800

65

780

67

760

68

740

70

710

73

680

-

650

-

620

-

Table

080( )-12B

80,000

High*

1/2

1775

38

1724

39

1652

40

1583

42

1505

44

1430

46

1343

49

1226

54

Low

808

-

751

-

717

-

679

-

641

-

595

-

538

-

430

-

 

Med-High**

1417

47

1385

48

1339

50

1280

52

1224

54

1163

57

1097

61

1013

66

 

 

 

Med-Low

 

1031

65

987

67

967

69

914

73

882

75

839

-

783

-

692

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.

 

 

High*

 

1840

-

1780

-

1700

41

1630

42

1550

45

1470

47

1380

50

1290

54

080( )-16B

80,000

Med-High**

1/2

1600

43

1560

44

1470

47

1400

49

1350

51

1280

54

1210

57

1150

60

 

Furnace

 

 

Med-Low

 

1380

50

1350

51

1300

53

1250

55

1190

58

1120

62

1040

67

960

-

 

 

Low

 

1100

63

1050

66

1000

69

950

-

900

-

850

-

800

-

750

-

 

 

 

 

 

 

 

High*

 

2215

30

2155

31

2090

32

2030

33

1975

34

1885

35

1810

37

1730

39

 

080( )-20B

80,000

Med-High

3/4

2000

33

1970

34

1930

35

1870

36

1820

37

1755

38

1695

39

1625

41

 

 

 

Med-Low

 

1670

39

1665

40

1660

41

1630

41

1590

42

1535

43

1470

45

1410

47

Airfl

 

 

Low**

 

1365

48

1360

49

1350

49

1340

50

1305

51

1300

51

1255

53

1225

54

100( )-16B

100,000

Med-High**

1/2

1640

53

1620

53

1540

56

1480

58

1420

61

1340

65

1250

69

1150

75

 

 

 

High*

 

1910

45

1860

47

1780

49

1700

51

1620

53

1520

57

1420

61

1310

66

ow

 

 

Med-Low

 

1440

60

1410

61

1370

63

1320

66

1270

68

1210

72

1140

-

1060

-

 

 

Low

 

1230

70

1210

72

1180

73

1140

-

1090

-

1030

-

960

-

880

-

Data

 

 

Med-Low

 

1650

51

1615

52

1605

53

1570

54

1540

55

1485

57

1435

59

1370

62

 

 

 

High*

 

2195

39

2140

40

2065

41

2000

42

1960

44

1860

46

1780

48

1695

50

 

100( )-20B

100,000

Med-High**

3/4

1975

43

1910

44

1875

45

1845

46

1805

47

1735

50

1670

51

1590

53

 

 

 

Low

 

1320

64

1300

65

1280

66

1275

67

1265

67

1250

68

1210

70

1160

73

 

 

 

High*

 

1860

56

1800

58

1730

60

1650

63

1570

66

1480

70

1380

75

1270

82

 

120( )-16C

120,000

Med-High**

1/2

1650

63

1610

65

1550

67

1480

70

1410

74

1320

79

1230

84

1120

-

 

 

 

Med-Low

 

1440

72

1410

74

1380

75

1320

79

1280

81

1220

85

1150

-

1080

-

 

 

 

Low

 

1230

84

1210

-

1180

-

1140

-

1090

-

1030

-

960

-

880

-

 

 

 

High*

 

2260

-

2200

-

2140

-

2070

-

1990

-

1910

-

1810

57

1710

61

 

120( )-20C

120,000

Med-High**

3/4

1870

56

1840

56

1790

58

1760

59

1710

61

1660

63

1610

65

1560

67

 

 

 

Med-Low

 

1540

67

1530

68

1510

69

1470

71

1430

73

1370

76

1300

80

1220

85

 

 

 

Low

 

1360

76

1330

78

1310

79

1280

81

1250

83

1220

85

1190

-

1150

-

CAPACITIES —Furnace Airflow Data

( ) Can be C or N

**Factory Set Cooling Speed

**Factory Set Heating Speed - Not Recommended

NOTES: 1. Airflow rates of 1800 CFM or more require two return air connections. Data is for operation with filter(s).

2.Temperature rises in the table are approximate. Actual temperature rises may vary.

3.Temperature rises and airflows for external static pressures greater than 0.5 are for reference only. These conditions are not recommended.

Page 6
Image 6
Nordyne RL 90+, RC 92+ installation instructions CAPACITIES -FurnaceAirflow Data, G6RC UPFLOW FURNACE, Can be C or N