Table
MTX Alarm Points Datafill Numbers for Metro RF Frame
Metro RF Frame Power Filter Alarm Points
Metro RF Frame # | Power Filter | Power Filter |
|
|
|
1 | 28 | 29 |
|
|
|
2 | 60 | 61 |
|
|
|
3 | 92 | 93 |
|
|
|
4 | 30 | 31 |
|
|
|
5 | 124 | 125 |
|
|
|
6 | 188 | 189 |
|
|
|
The MTX Datafill alarm points for the CE frame are shown in Table
Table
MTX Alarm Points Datafill Numbers for Metro CE Frame components
Alarm | Alarm | Alarm | Alarm | Alarm | Alarm | Alarm | Alarm |
name | point | name | point | name | point | name | point |
|
|
|
|
|
|
|
|
HSMO +27V A | 128 | HSMO +27V B | 129 | HSMO #1 | 130 | HSMO #2 | 131 |
|
|
|
|
|
|
|
|
CSM2 | 132 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
RMC +27V A1 | 134 | RMC +27V B1 | 135 | RMC +27V A2 | 136 | RMC +27V B2 | 137 |
|
|
|
|
|
|
|
|
RMC LNA1 | 138 | RMC LNA2 | 139 | RMC LNA3 | 140 | RMC LNA4 | 141 |
|
|
|
|
|
|
|
|
RMC LNA5 | 142 | RMC LNA6 | 143 | RMC LNA7 | 144 | RMC LNA8 | 145 |
|
|
|
|
|
|
|
|
RMC LNA9 | 146 | RMC LNA10 | 147 | RMC LNA11 | 148 | RMC LNA12 | 149 |
|
|
|
|
|
|
|
|
ICRM 1 | 152 | ICRM 2 | 153 | ICRM 3 | 154 | ICRM 4 | 155 |
|
|
|
|
|
|
|
|