| DualMode Metrocell Cell Site Specifications |
Earthquake | Meet earthquake requirements of Zone 1 |
| and Zone 2 as defined by Bellcore |
| |
Fixed equipment anchorage. |
|
Thermal dissipation for Metrocell RF Frame:
Component | Dissipation per | Maximum | Total | |
| unit | number of units | dissipation | |
|
|
|
| |
TRU | 27 W | 24 | 648 W | |
|
|
|
| |
PA | 89 W | 24 | 2136 W | |
|
|
|
|
|
Combiner | 21 W | 24 | 504 | W |
|
|
|
|
|
Duplexer | 9.3 W | 3 | 28 | W |
|
|
|
| |
|
| Total | 3.3 KW | |
|
|
|
|
|
Regulatory
Electromagnetic Emissions
Cell site equipment complies with the following Regulatory Specification:
•FCC part 22 for 800 MHz frequency
•FCC part 15 Class B for cell site with Universal CE Frame and Metro RF Frame (except for the ICRM, CSM, HSMO and ACU shelves located on the Universal CE Frame)
•DOC
Radiated Emissions
Cell site equipment complies with the following Regulatory Specification:
•FCC Part 22 for 800 MHz frequency
•FCC Part 15 Class B for cell site with Universal CE Frame and Metro RF Frame (except for the ICRM, CSM, HSMO and ACU shelves located on the Universal CE Frame)
•Bell Canada Design Standard TAD 8465 of Bellcore
Telecom Compliance
Cell site equipment complies with the following Regulatory Specification:
•CS03, Issue 7, Part 2 (Table 1: Digital Interface Requirement, Type IV)
•FCC Part 68 (TSB31, Table