Nortel Networks 411-2021-111 manual Regulatory Electromagnetic Emissions, Radiated Emissions

Models: 411-2021-111

1 98
Download 98 pages 40.1 Kb
Page 91
Image 91

 

DualMode Metrocell Cell Site Specifications 7-5

Earthquake

Meet earthquake requirements of Zone 1

 

and Zone 2 as defined by Bellcore

 

TR-NWT-000063

Fixed equipment anchorage.

 

Thermal dissipation for Metrocell RF Frame:

Component

Dissipation per

Maximum

Total

 

unit

number of units

dissipation

 

 

 

 

TRU

27 W

24

648 W

 

 

 

 

PA

89 W

24

2136 W

 

 

 

 

 

Combiner (-4.5 dB)

21 W

24

504

W

 

 

 

 

 

Duplexer (-0.7 dB)

9.3 W

3

28

W

 

 

 

 

 

 

Total

3.3 KW

 

 

 

 

 

Regulatory

Electromagnetic Emissions

Cell site equipment complies with the following Regulatory Specification:

FCC part 22 for 800 MHz frequency

FCC part 15 Class B for cell site with Universal CE Frame and Metro RF Frame (except for the ICRM, CSM, HSMO and ACU shelves located on the Universal CE Frame)

DOC RSS-128 Issue 1.0 Dual Mode Capability in Canada

Radiated Emissions

Cell site equipment complies with the following Regulatory Specification:

FCC Part 22 for 800 MHz frequency

FCC Part 15 Class B for cell site with Universal CE Frame and Metro RF Frame (except for the ICRM, CSM, HSMO and ACU shelves located on the Universal CE Frame)

Bell Canada Design Standard TAD 8465 of Bellcore TR-NWT-001089 in 10 kHz to 30 MHz and 1 GHz to 10 GHz range for radiated emission

Telecom Compliance

Cell site equipment complies with the following Regulatory Specification:

CS03, Issue 7, Part 2 (Table 1: Digital Interface Requirement, Type IV)

FCC Part 68 (TSB31, Table 4.5-2: Test Requirement Matrix)

DMS-MTX DualMode Metrocell Cell Site Description

Page 91
Image 91
Nortel Networks 411-2021-111 manual Regulatory Electromagnetic Emissions, Radiated Emissions, Telecom Compliance