DualMode Metrocell Cell Site Specifications 7-3

DC Power Requirements

 

Grounding

As specified in Northern Telecom’s

 

NTP-297-1001-156

Voltage

Nominal +27.0 Vdc ±0.5 Vdc

 

Range +21.0 Vdc to 29.0 Vdc

Ripple

400 millivolts

Spurious 0.005 - 10 MHz

< -55 dBm @ 0.3 to 3.4 kHz

Noise

< 32 dBrnC (600 ohms bridged)

Voltage stability

±1% of pre-set voltage @ 0-100% load

Voltage response

< 600 ms for a step of 10-70% load

Voltage over/under shoot

< 20% of pre-set voltage for a step of

 

10-70% load

Power Distribution Requirements

 

Channel/Frames

Current Breakers

Mechanical

 

Rack dimension

Height 84" (213.4 cm)

 

Width 22" (56 cm)

 

Depth 24" (61 cm), including cables and

 

excluding unit handles

Clearance and Access

Ceiling 8 feet (7.5 feet. after cable tray

 

installation

 

Front aisle 3 feet

 

Rear aisle 2 feet

 

Building access door are required to be a

 

minimum of 30 inches wide

Weight CE frame

400 lb. @ 80 lb./sq. ft.

RF Frame

950 lb. @ 115 lb./sq. ft.