| DualMode Metrocell Cell Site Specifications |
DC Power Requirements |
|
Grounding | As specified in Northern Telecom’s |
| |
Voltage | Nominal +27.0 Vdc ±0.5 Vdc |
| Range +21.0 Vdc to 29.0 Vdc |
Ripple | 400 millivolts |
Spurious 0.005 - 10 MHz | < |
Noise | < 32 dBrnC (600 ohms bridged) |
Voltage stability | ±1% of |
Voltage response | < 600 ms for a step of |
Voltage over/under shoot | < 20% of |
| |
Power Distribution Requirements |
|
Channel/Frames | Current Breakers |
Mechanical |
|
Rack dimension | Height 84" (213.4 cm) |
| Width 22" (56 cm) |
| Depth 24" (61 cm), including cables and |
| excluding unit handles |
Clearance and Access | Ceiling 8 feet (7.5 feet. after cable tray |
| installation |
| Front aisle 3 feet |
| Rear aisle 2 feet |
| Building access door are required to be a |
| minimum of 30 inches wide |
Weight CE frame | 400 lb. @ 80 lb./sq. ft. |
RF Frame | 950 lb. @ 115 lb./sq. ft. |