7-4DualMode Metrocell Cell Site Specifications

Paint

Maple Brown # SCP-717-R1

Marking

Nortel Logo

Packaging

 

Frames

ShockAir bubble sheet and Styrofoam

 

packaging material

Vibration

Styrofoam sandwich pallet

Bracing and support

Wood, 2 x 4 braces

Moisture

5 mil polyethylene

Transport

Air ride shock

Modules

Separate shipping carton

Environmental

Operating temperature

 

Normal operation

+5°C to +40°C (+41°F to +105°F)

Short-term operation

0°C to +50°C (+32°F to 120°F)

Note: Short-term refers to a period of not more than 72 consecutive hours and a total of not more than 15 days in one year.

Thermal cycling

Capable of withstanding the changes in

 

temperature at the rate of 1°C (1.8°F) in

 

three minutes over the short-term operating

 

temperature range

Operating Relative Humidity

20 to 95% (non-condensing) over nominal

 

temperature range and not to exceed 0.024

 

lb of water/lb of dry air

Altitude

61 meters (200 feet) below sea level to

 

4000 meters (13,000 feet) above sea level

Shock and vibration

Screw lock on required modules

411-2021-111 Standard 01.01 June 1996

Page 90
Image 90