Nortel Networks 5000BH manual Using the 8-port TokenSpeed and TokenSpeed/MCP Switch Modules, 3-10

Models: 5000BH

1 70
Download 70 pages 41.38 Kb
Page 38
Image 38
Factory default configuration settings (continued)

Using the 8-port TokenSpeed and TokenSpeed/MCP Switch Modules

Table 3-3.

Factory default configuration settings (continued)

 

 

 

Parameter

Factory default

Possible settings

 

 

 

Filters

Disabled

Disabled, Enabled

Note: Do not enable both NetBIOS filtering and packet filtering on the same port. When both types of filtering are enabled, only the NetBIOS filtering is active.

Bridge group

1

1–32

Virtual ring number

For ports 1 through 8 on each slot in

1–FFE

(Valid only when source route

hexadecimal format:

 

bridging is selected.)

Slot 1: 11, 12, 13, 14, 15, 16, 17, 18

 

 

Slot 2: 21, 22, 23, 24, 25, 26, 27, 28

 

 

Slot 3: 31, 32, 33, 34, 35, 36, 37, 38

 

 

Slot 4: 41, 42, 43, 44, 45, 46, 47, 48

 

 

Slot 5: 51, 52, 53, 54, 55, 56, 57, 58

 

 

Slot 6: 61, 62, 63, 64, 65, 66, 67, 68

 

 

Note: The Centillion 50 switch contains only slots 1 through 3.

Priority

128

0–255

(Valid only when source route

 

 

bridging is selected.)

 

 

Path cost

16

1–65535

(Valid only when source route

 

 

bridging is selected.)

 

 

ARE hop count

7

1–7 or 1–13

(Valid only when source

 

 

route bridging is selected.)

 

 

STE hop count

7

1–7 or 1–13

(Valid only when source route

 

 

bridging is selected.)

 

 

SR broadcasting

Auto

Auto, Off, On

(Valid only when source route

 

 

bridging is selected.)

 

 

 

 

 

If the factory default settings are not appropriate for your network, you may be able to use one of the predefined switch configurations that are available in SpeedView. You simply choose one of these without having to configure individual ports.

3-10

893-01019-A

Page 38
Image 38
Nortel Networks 5000BH manual Using the 8-port TokenSpeed and TokenSpeed/MCP Switch Modules, 3-10, 893-01019-A