2 SafeCom Go Canon

2.9.2Older Canon devices

1.Open a web browser and enter the IP address of the MFP in the address field followed by :8000/sms. Example:

http://172.16.6.55:8000/sms

Use of JavaScript (Active Scripting) must be enabled in the browser.

2.Enter Password. The default SMS password is: MeapSmsLogin.

3.Click Log In.

Stop and uninstall SafeCom Go:

4.In the browser in the Application List select SafeCom Go. Click Stop.

5.In the Application List select SafeCom Go. Click Uninstall.

6.Click OK.

Change Login Service to Default Authentication:

7.Click on the System Management tab.

8.Click on the Enhanced Sys. App tab.

9.In the Login Service section select Default Authentication. Click Select.

Restart the MFP:

10.On the control panel press and hold the power button to restart the MFP. Uninstall SafeCom Go Login:

11.In the browser click on the System Management tab.

12.Click on the Enhanced Sys. App tab.

13.In the Login Service section select SafeCom Go Login. Click Uninstall.

14.Click OK.

D60707-18

30

Page 31
Image 31
Nuance comm D60707-18 manual Older Canon devices, Application List select SafeCom Go. Click Uninstall