2 SafeCom Go Canon

18.On the control panel press and hold the power button to restart the MFP. The Restart… device command in SafeCom Administrator does NOT work with Canon MFPs.

2.5Specify SafeCom Server and register device

1.Open a web browser and enter the address of the MFP in the address field followed by :8000/safecom. Example:

http://172.16.6.55:8000/safecom

Use of JavaScript (Active Scripting) must be enabled in the browser.

If a System Manager is defined (2.8.8) then enter System Manager ID and System PIN and click Administrator Login to access all the Canon web pages. Clicking General User Login instead will give limited access where it is not possible to control management settings and restart the Canon device remotely.

2.Click Configuration on the menu to access the SafeCom Configuration web page (2.7.3). Type admin for the user name, type your password (default is nimda) and then click OK.

3.Enter Group name, Server address and TCP port (default is 7500). If the SafeCom server is clustered you must enter the address of the virtual server.

4.Click Apply.

5.Click Register on the menu to access the SafeCom Register web page (2.7.4).

6.Use the built-in Technician account to register the device. Enter the User logon (default is TECH) and PIN code (default is 1234).

7.Click Register.

D60707-18

15

Page 16
Image 16
Nuance comm D60707-18 manual Specify SafeCom Server and register device, Click Register