Select Menu Item 1 Command

ASCII

Hexadecimal

 

Decimal

 

 

 

 

ESC DLE D Pno Pa1 Pb1

1B 10 44 Pno Pa1

Pb1

27 16 68 Pno Pa1 Pb1

Pa2 Pb2...Pan Pbn

Pa2 Pb2...Pan Pbn

 

Pa2 Pb2...Pan Pbn

 

 

 

 

This command is used to set the menu.

Parameter Pno

Designates the number of parameter bytes since the designated number. Invalid with MSB.

• 00H £Pno £FFH

Pno = 00H or 01H, an initial setting (menu setting for current conditions) will be performed, but the menu contents not be changed.

Parameter Pa

Determines the item number in the menu.

Bit 6 = 1 allows the recognition of Pa parameter.

MSB is invalid.

40H £Pa £7FH

C0H £Pa £FFH

Parameter Pb

Pb : determines the setting values of the menu.

Bit 6 = 0 allows the recognition of Pa parameter.

MSB is invalid.

00H £Pb £ £FH

0H £Pb £BFH