Specifications
Recording medium:
Overall frequency:
HQ mode: 200 to 7,900 Hz
SP mode: 300 to 4,700 Hz
LP mode: 300 to 2,900 Hz
Recording time:
HQ mode: Approx. 81 h.
SP mode: Approx. 215 h. 50 min.
LP mode: Approx. 1208 h. 30 min.
HQ mode: Approx. 40 h. 30 min.
SP mode: Approx. 107 h. 55 min.
LP mode: Approx. 604 h. 15 min.
HQ mode: Approx. 20 h. 5 min.
SP mode: Approx. 53 h. 40 min.
LP mode: Approx. 300 h. 30 min.
Microphone:
Electret Condenser Microphone (monaural)
Speaker:
Maximum power: 120 mW
Earphone jack (monaural):
ø3.5 mm diameter, impedance 8 Ω
Microphone jack (monaural):
ø3.5 mm diameter, impedance 2 kΩ
Power supply:
Two AAA (LR03) batteries or Two Ni- MH rechargeable batteries
Continuous battery:
Alkaline batteries:Approx. 39 h.
Ni- MH rechargeable batteries: Approx. 22 h.
Dimensions:
102 (L) x 36 (W) x 20.5 (T) mm Weight: 63 g (including battery)
•Battery life is measured by Olympus. It varies greatly according to the type of batteries used and the conditions of use.
•Your recorded contents are for your personal use or pleasure only. It is prohibited to record copyrighted material without permission of the copyright holders according to copyright law.
•Specifications and design are subject to change without notice for improvement of performance.
Accessories (Optional)
BR401
Connecting cord (Earphone jack ↔
Microphone jack):
KA333
ME52
Electret condenser microphone:
ME15
Telephone pickup: TP7
“CE” mark indicates that this product complies w i t h t h e E u r o p e a n requirements for safety, health, environment and customer protection.
This symbol [crossed-
out wheeled bin WEEE Annex IV ] indicates separate collection of waste electrical and electronic equipment in
the EU countries.
Please do not throw the equipment into the domestic refuse.Please use the return and collection systems available in your country for the disposal of this product.
Applicable Product:
This symbol [crossed-
o u t w h e e l e d b i n Directive 2006/66/EC A n n e x I I] i n d i c ate s separate collection of waste batteries in the
EU countries. Please do not throw the batteries into the domestic refuse. Please use the return and collection systems available in your country for the disposal of the waste batteries.
EN 11