5.3Specifications
5.3.1Functional
System Design
Measurement Principle
Input
Measured Variable
Zero and Span
User Interface
Keypad
Indication
Digital Communication
Interoperability test kit (ITK Revision)
LAS capable
Minimum Operating Voltage
Quiescent Current Draw
DEV Revision
Function Blocks
Damping
Power (Measured at instrument terminals)
Fieldbus General Purpose/Explosion Proof 9 to 32 VDC (17 mA maximum current draw)
FISCO/FNICO | |
Housing |
|
Material | Aluminum A356T6 (<0.20% copper), optional 316 stainless steel |
Cable Entry | 3⁄4" NPT and M20 |
5.3.2 Performance
Accuracy |
|
| ±0.015" |
Repeatability |
|
| ±0.005% of full span or 0.005" (0.127 mm) (whichever is greater) |
|
|
|
|
Linearity |
|
| 0.020% of full span or 0.031" (0.794 mm) (whichever is greater) |
Maximum level rate of change | 6 inches per second | ||
|
|
|
|
Response time |
|
| 0.1 second |
|
| <5 second | |
|
|
|
|
Upper dead zone |
|
| None |
Lower dead zone |
|
| <2" (5 cm), SIL 2: <5" (13 cm) |
|
|
| |
Ambient temperature range | Transmitter: | ||
|
| LCD: | |
|
|
| |
Process temperature | External Mount: | ||
|
|
| |
|
|
|
|
|
| Direct Insertion: | |
| High temperature probe: | ||
|
|
| |
Humidity | 0 to 99% |
| |
Electromagnetic compliance |
| EN 61326 | |
|
| ||
Maximum Pressure (Direct Insertion) | 1700 psig @ +100° F | ||
|
|
| (limited to the pressure rating of the selected flange or float) |