2.3.3Operational Considerations

2.3.3Operational Considerations

Exterior ambient temperature of the service should not exceed the design specifications of the electronics (-40° to +175° F (-40° to +80° C)). The operating temperature limits of the LCD are -5° to +160° F (-20° to +70° C). Temperatures below -5° F will cause the display to tem- porarily white out, and temperatures above +160° F will cause the display to go temporarily black. It will recover without damage when the operating temperature range returns. A sunshade should be used if electronics are mounted in direct sunlight.

Maximum process temperature for direct insertion transmitters is +500° F (+260° C). Externally mounted transmitters can be used with process temperatures up to +800° F (+427° C) if the MLI is equipped with an insulation blanket from the factory.

2.3.4 Configuration Information

Some key information is needed to configure the Jupiter transmitter. Complete the following operating parameters table before beginning configuration.

Display

Question

Answer

Units

What units of measurement will be

 

 

used? (inches or centimeters)

_____________

Probe

What probe length is listed on the

 

Length

model information?

_____________

Measurement

Choose from Level Only or

 

Type

Level and Interface

_____________

Sensor

Choose from MLI Top, MLI Bottom,

 

Mount

Direct Insertion Near (NPT, BSP,and

 

 

600# or less flanges) or

 

 

Direct Insertion Extended (Flanged

 

 

probes 900# class and over)

_____________

2.4 Mounting

2.4.1 External

Caution: Do not rotate the Jupiter electronics enclosure. Rotating the electronics enclosure could cause damage to sensor cables.

If ordered from the factory with the MLI, it will be attached to the gauge and configured for the measuring range specified at the time of order placement. If not, use the following directions:

1. Place the Jupiter transmitter and mounting clamps in a convenient location.

Figure 1

Mounting External Jupiter

46-649 Jupiter Magnetostrictive Transmitter - FOUNDATION fieldbus™

6