Orion 2xx manual Appendix - Transducer Block Parameters, 5.6References

Models: 2xx

1 36
Download 36 pages 17.03 Kb
Page 34
Image 34
5.6References

5.6References

1.FOUNDATION fieldbus, A Pocket Guide Ian Verhappen, Augusto Pereira

2.FOUNDATION fieldbus—System Engineering Guidelines, AG–181

Appendix – Transducer Block Parameters

ITEM

PARAMETER NAME

PARAMETER LABEL

0

BLOCK_STRUCTURE

BLOCK STRUCT

1

ST_REV

ST REV

2

TAG_DESC

TAG DESC

3

STRATEGY

STRATEGY

4

ALERT_KEY

ALERT KEY

5

MODE_BLK

MODE BLK

6

BLOCK_ERR

BLOCK ERR

7

UPDATE_EVT

UPDATE EVT

8

BLOCK_ALM

BLOCK ALM

9

TRANSDUCER_DIRECTORY

XD DIRECTORY

10

TRANSDUCER_TYPE

XD TYPE

11

XD_ERROR

XD ERROR

12

COLLECTION_DIRECTORY

COLLECT DIR

13

LEVEL

Level

14

LEVEL_UNIT

Level Unit

15

PROBE_LEVEL

Probe Level

16

PROBE_LEVEL_UNIT

Probe Level Unit

17

SENSOR_VALUE

Sensor Value

18

SENSOR_UNIT

Sensor Unit

19

SENSOR_OFFSET

Sensor Offset

20

CAL_TYPE

Cal Type

21

CAL_POINT_LO

Cal Point Lo

22

CAL_POINT_HI

Cal Point Hi

23

PROBE_LEVEL_LO

Probe Lvl Lo

24

PROBE_LEVEL_HI

Probe Lvl Hi

25

LEVEL_OFFSET

Level Offset

26

SENSOR_HIGH_LIMIT

Sensor Hi Lmt

27

SENSOR_LOW_LIMIT

Sensor Lo Lmt

28

MEASUREMENT_TYPE

Measurement Type

29

PROBE_LENGTH

Probe Length

30

DEADBAND

Deadband

31

SENSOR_MOUNT

Sensor Mount

32

TRIM_LEVEL

Trim Level

33

INTERFACE

Interface

ITEM

PARAMETER NAME

PARAMETER LABEL

34

INTERFACE_UNIT

Interface Unit

35

TRIM_INTERFACE

Trim Interface

36

ENTER_PASSWORD

Enter Password

37

NEW_PASSWORD

New User Password

38

DEVICE_STATUS

Device Status

39

HISTORY_MESSAGE

History Message

40

HISTORY_CONTROL

History Control

41

RESET_HISTORY

Reset History

42

FLOAT_1_COUNTS

F1 Counts

43

FLOAT_2_COUNTS

F2 Counts

44

CONVERSION_FACTOR

Conv Factor

45

SCALE_OFFSET

Scale Offset

46

FLOAT_1_THRESHOLD

F1 Threshold

47

FLOAT_1_POLARITY

F1 Polarity

48

FLOAT_2_THRESHOLD

F2 Threshold

49

FLOAT_2_POLARITY

F2 Polarity

50

SENSITIVITY

Sensitivity

51

DRIVE_AMPLITUDE

Drive Amplitude

52

MINIMUM_SEPARATION

Min Separation

53

ELECTRONICS_TEMPERATURE

Elec Temp

54

MAX_ELECTRONICS_TEMPERATURE

Max Elec Temp

55

MIN_ELECTRONICS_TEMPERATURE

Min Elec Temp

56

RESET_ELECTRONICSTEMPERATURE

Reset Elect Temp

57

LCD_LANGUAGE

LCD Language

58

FACTORY_PARAM_1

Factory Param 1

59

FACTORY_PARAM_2

Factory Param 2

60

ECHO_SUMMARY

Echo Summary

61

ECHO_DATA

Echo Data

62

ECHO_DATA_INDEX

EchoData Indx

63

NON_VOL_STAT

Non Vol Stat

64

DATE_CODE

Date Code

65

ORION_SERIAL_NUMBER

Orion S/N

66

FIRMWARE_VERSION

Firmware Ver

67

COPROCESSOR_VERSION

Coprocessor Ver

31

46-649 Jupiter Magnetostrictive Transmitter - FOUNDATION fieldbus™

Page 34
Image 34