Modem Command Reference

Register Descriptions

S0 — Number of Rings Till Auto-Answer

Range

0-255 rings

Default0

Establishes the number of rings required before the modem answers the incoming calls. Setting this register to zero disables auto-answer mode.

S1 — Ring Counter

Range

0-255 rings

Default0

Number of rings which the modem detects before it answers a call. If no rings occur over an eight second interval, the register is cleared.

S2 — Escape Character

Range

0-255, ASCII decimal

Default43

S2 holds the decimal value of the ASCII character used as the escape character. The default value corresponds to an ASCII '+'. A value over 127 disables the escape process, i.e., no escape character will be recognized.

S3 — Carriage Return Character

Range

0-127, ASCII decimal

Default

13 (Carriage Return)

Sets the command line and result code terminator character. Pertains to asynchronous operation only.

S4 — Line Feed Character

Range

0-127, ASCII decimal

Default

10 (Line Feed)

Sets the character recognized as a line feed. Pertains to asynchronous operation only. The Line Feed control character is output after the Carriage Return control character if verbose result codes are used.

User’s Guide and Reference

4 - 37

Page 69
Image 69