Section Five

Remote Digital Loopback with Self- Generated Pattern

This procedure tests the remote Modem port, the telephone line, the local serial and Modem ports. The test is only functional when the Modem is in direct mode (&Q0) and the COM port baud rate is set to 14400 bps (Trumpcard 14400) / 28800 bps (Trumpcard 28800) or less.

This test is similar to the Remote Digital Loopback test.

In this test, the local Modem sends the remote Modem a special test data sequence and the remote Modem echoes the data back. The local Modem examines the returned data and establishes an error count each time a mismatch is detected.

To run this test:

1.Establish a connection with a remote Modem.

2.Enter AT&T4 [ENTER] to ensure that the remote operator has set the Modem to accept a Remote Digital Loopback request.

3.Enter AT&T7 [ENTER] to initiate the remote digital loopback test. The Modem will send a test pattern to the remote Modem.

4.Enter AT&T0 [ENTER] to end the test. The Modem will return a three- digit number showing the test results. If the result is 000, the local and remote modems, and the telephone line have passed the test.

5 - 6

Trumpcard 14400/28800 Modem

Page 84
Image 84
Ositech comm Trumpcard Data/Fax Modem manual Remote Digital Loopback with Self- Generated Pattern