Modem Command Reference
&Gn — Set Guard Tone
Parameters | 0, 1, or 2 |
Default0
Normally, controls the generation of guard tone. This command is not implemented; however, the command structure is provided for application compatibility.
&Jn — T elephone Jack Selection
Parameters | 0 or 1 |
Default0
The command structure is provided for application compatibility only and performs no function.
&Kn — DTE/Modem Flow Control
Parameters | 0, 3, 4, 5 or 6 |
Default3
Determines how the modem controls the flow of data between the communications software and the modem. When the modem terminal buffer is nearly full, the modem will either send an XOFF command, or drop CTS to stop the data flow. When the buffer is nearly empty, the modem will either send an XON command, or raise CTS to start the data flow.
The modem also responds to XON/XOFF characters, or RTS stimulus from the communications software by suspending or resuming transmission accordingly. The modem responds to XON/XOFF characters and also passes the XON/XOFF characters to the remote modem as data if transparent flow control is selected. When in Direct mode (&Q0), flow is not used and the modem ignores the setting of this command.
Examples
AT&K0 | Disables flow control |
AT&K3 | Enables RTS/CTS flow control |
AT&K4 | Enables XON/XOFF flow control |
AT&K5 | Enables transparent XON/XOFF flow control |
AT&K6 | Enables RTS/CTS and XON/XOFF flow control |
User’s Guide and Reference | 4 - 21 |