Section Four

S18 — Test Timer

Range

0-255 seconds

Default0

Sets the length of time the modem conducts a test before returning to the command mode. If this register is zero, the test will not automatically terminate; the test must be terminated from the command mode by issuing an &T0 or H command.

S24 — Sleep Inactivity Timer

Range

0-255 seconds

Default

10 seconds

Sets the length of time, in seconds, that the modem will wait before entering power down sleep mode. The time is reset by any data activity or telephone line activity. A value of zero will disable power down sleep mode.

S25 — Delay to DTR

Range

0-255 (hundredths of a second)

Default5

Achange in /DTR (ON-to-OFF) that persists for a period shorter than the value held in S25 is ignored by the modem while it is in data mode.

S30 — Inactivity Timer

Range0-255

Default

0 (disabled)

Determines the length of time, in ten-second intervals, that the modem will wait before disconnecting when no data is sent or received. In MNP or V.42 mode, any data transmitted or received will reset the timer. In other modes, any data transmitted will reset the timer. The inactivity timer is inoperative in synchronous mode.

4 - 40