Modem Command Reference
S32 — XON Character
Range
Default 17
Sets the value of the XON character.
S33 — XOFF Character
Range
Default 19
Sets the value of the XOFF character
S36 — LAPM Failure Control
Range0-7
Default7
This register is used when the S48 register contains the value 128 and an attempted error correction link fails. These fallback options are initiated immediately upon connection if S48 = 128.
If an invalid number is entered, the number is accepted into the register, but S36 will act as if the default value is entered.
The S36 actions are:
S36 = 0 | Modem disconnects. |
S36 = 1 | Modem stays |
| is established. |
S36 = 2 | Reserved. |
S36 = 3 | Modem stays |
| connection is established. |
User’s Guide and Reference | 4 - 41 |