Modem Command Reference

S32 — XON Character

Range 0-255

Default 17

Sets the value of the XON character.

S33 — XOFF Character

Range 0-255

Default 19

Sets the value of the XOFF character

S36 — LAPM Failure Control

Range0-7

Default7

This register is used when the S48 register contains the value 128 and an attempted error correction link fails. These fallback options are initiated immediately upon connection if S48 = 128.

If an invalid number is entered, the number is accepted into the register, but S36 will act as if the default value is entered.

The S36 actions are:

S36 = 0

Modem disconnects.

S36 = 1

Modem stays on-line and a Direct mode connection

 

is established.

S36 = 2

Reserved.

S36 = 3

Modem stays on-line and a Normal mode

 

connection is established.