[Setup] initial setting screen

[System1] setting

This is used to perform a variety of settings.

R1

 

R2

 

R3

 

R4

 

R5

 

 

 

 

 

 

 

 

 

 

 

 

 

The rotary 2 control is used to set the amount of delay for

System1

 

Dly

 

Time

 

GPI

 

RS422

the source input when the [AdvRef] advanced reference

 

 

1Frame

 

Sec

 

ME

 

GVG

signal is connected with the 3D optional board (AG-VE70)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1Frame

 

 

Sec

 

 

ME

 

 

GVG

 

installed. If 0Frame is selected, the video delay amount is

 

 

 

 

 

 

 

 

 

 

 

0Frame

 

 

Frame

 

 

DSK

 

 

SONY

 

different between when the 3D effects are applied and when

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fade

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

they are not. The default setting is 1Frame. The setting is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

fixed at 0Frame when the 3D optional board is not installed.

 

 

 

 

 

 

 

 

 

 

 

 

 

The audio source delay amount is also set according to this setting.

[Sec] (seconds + frames) or [Frame] (frames) only is selected for the time display using the rotary 3 control. The default setting is [Sec].

Whether [ME], [DSK] or [Fade] is to be executed by GPI can be set using the rotary 4 control. The default setting is [ME]. [GVG] or [SONY] can be selected as the RS-422A protocol using the rotary 5 control. The default setting is [GVG].

[System2] setting

The time taken until the LCD is set to the power saving

R1

 

R2

 

R3

 

R4

 

 

R5

 

 

 

 

 

 

 

 

 

 

 

 

mode can be selected using the rotary 2 control.

System2

 

LCDStby

 

VBClean

 

DR

 

 

 

With the 0 setting, the display is always on. The time can

 

0

 

 

Off

 

 

On

 

be set in 10-minute increments from 0 to 60. The default

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 - 60

 

 

On

 

 

On

 

 

 

setting is 0.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Off

 

 

Off

 

 

 

[On] or [Off] is selected using the rotary 3 control to set

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

whether or not cleaning is to be performed inside the vertical

 

 

 

 

 

 

 

 

 

 

 

 

blanking period (VBlk). The default setting is [Off].

 

 

 

 

 

 

 

 

 

 

 

 

[On] or [Off] is selected using the rotary 4 control to set whether or not the [DR] (dynamic rounding) is to be performed. The default setting is [On].

<Note>

Selecting [Off] for [VBClean] may result in a deviation in the amount of delay between the video signals and vertical blanking signals depending on the setting for the [Dly] item among the [System1] settings and on whether the 3D optional board (AG- VE70) has been installed.

[Bus] setting

AB (AB bus) or PrgPre (program/preset system) can be

R1

 

R2

 

R3

 

R4

 

R5

 

 

 

 

 

 

 

 

 

 

 

 

 

selected as the bus system using the rotary 2 control. The

Bus

 

Type

 

Still

 

Audio

 

Tally

default setting is AB.

 

 

AB

 

On

 

CP

8

 

[On] (initiate Still) or [Off] (do not initiate Still) when cross

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AB

 

 

On

 

 

CP

 

 

8

 

points are to be changed is selected using the rotary 3

 

 

 

 

 

 

 

 

 

 

 

Prg Pre

 

 

Off

 

 

1, 2

 

 

EXT

 

control. The default setting is [On].

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The Audio MIX system can be selected using the rotary 4

 

 

 

 

 

 

 

 

 

 

 

 

 

control.

 

 

 

 

 

 

 

 

 

 

 

 

 

At the [CP] setting, two audio sources allocated to the selected cross point are output. At the [1,2] setting, the audio sources 1, 2 allocated to the cross point are mixed at all times. The default setting is [CP].

[8]or [EXT] can be selected using the rotary 5 control as the setting for the eight tally outputs. At the [8] setting, the tally signal is output when cross point 8 has been selected; at the [EXT] setting, it is output when EXT has been selected.

<Note>

When [Still] is to be set to [Off], do not mix the analog and SDI signals for the input. Be absolutely sure to use the analog-only system or SDI-only system.