Emergency eject
If the cassette is not ejected even when the EJECT button is pressed, use a screwdriver or oth- er implement to push down and simultaneously turn the EMERGENCY screw. This will enable the cassette to be ejected.
1 Turn off the power of the VTR.
2
3 While pressing on the screwdriver, continue to turn the EMERGENCY screw in the counter- clockwise direction until the cassette moves up.
4
5
Take out the cassette.
Return the rubber cap to its original position.
Note{
1.Do not turn the EMERGENCY screw unless it is an emergency.
2.Do not turn the screw in the clockwise direction. After the cassette has moved up, do not turn the screw any further. Otherwise, the mechanism may be damaged.
3.After the cassette has moved up, the cassette holder will not lock even when it is closed. Before closing the cassette holder, be absolutely sure to turn the power off and back on again to reset the mechanism’s operation.
Cassette holder
A Turn off the power.
C
EMERGENCY screw | Push and turn |
simultaneously.
B
Error Codes
When an error occurs in the unit for some reason or other, the following error codes appear in the display window.
Code | Contents | |
No. | ||
| ||
|
| |
8 | Solenoid trouble | |
|
| |
9 | The servo is not locked. | |
|
| |
A | Condensation has occurred. | |
|
| |
B | Supply reel trouble | |
|
| |
C | ||
|
| |
D | Capstan trouble | |
|
| |
E | Cylinder trouble | |
|
| |
F | Loading trouble | |
|
|