Setting the Electronic Shutter
Changing the Shutter Speed/Mode Selection Range
The shutter speed selection range can be limited to the required range and whether to use a SYNCHRO SCAN mode can be selected at the SHUTTER SPEED page of the setting menu. The unit is set so that the SHUTTER SPEED page is not displayed when shipped from the fac- tory. To operate the SHUTTER SPEED page, switch the unit to engineer mode or select the SHUTTER SPEED page at the MENU SELECT page beforehand.
1 Set the MENU SET/OFF switch to SET.
The page on which the previous setting menu operations were completed appears on the viewfinder screen. (When the menu is used for the first time, the first page appears.)
2 Press the PAGE button repeatedly until the SHUTTER SPEED page shown below appears. (This operation can also be performed using the PAGEoUP/DOWN function.)
- SHUT T ER SPEED -
¢ESYNCHRO SCAN
E1 / 1 0 0
E1 / 1 2 0
E1 / 2 5 0
E1 / 5 0 0
E1 / 1 0 0 0
Note{
The ON/OFF status for each item is indicated by displaying an asterix (E) or period (.) in front of the item on the screen.
3
4
5 When menu operations have been completed, set the MENU SET/OFF switch to OFF. The setting menu disappears from the viewfinder screen and the displays indicating the unit’s current status appear at the top and bottom of the viewfinder screen.
Note{
When operating the unit from the
ÁSee “Setting Menu Configuration” (page 47) for a description of engineering mode and select- ing display pages.
Changing the lris Automatic Adjustment Reference Value
To change the reference value, change the A. IRIS LEVEL, A. IRIS PEAK/AVE, A. IRIS MODE value on the LEVEL 6/6 page of the setting menu using the UP or DOWN button.