Set the zoom ring to the wide-angle position.
Loosen the Ff ring clamping screw.
Set the zoom ring to the telephoto position manually or by electric drive.
Set the lens iris to manual.

Adjusting the Lens Flange

When images are not clearly focused at both the telephoto and wide-angle positions during zoom operations, adjust the flange back (the distance from the lens mounting surface to the im- age formation surface).

Once adjusted, the flange back does not need to be readjusted as long as the lens is not changed.

Adjustment method

Check the position of each part of the lens which must be operated in order to adjust the flange back with the lens Handling Instructions.

Approx. 3 m

Adjusting the Flange Back

1

2 Open the iris. Position the flange back adjustment chart about 3 m from the lens and illumi- nate it so that an appropriate image output level is obtained.

If the image level is too high, use the CC/ND filters or the shutter.

3

4

5 Shoot the flange back adjustment chart and turn the distance ring to bring the chart into focus.

6

7 Turn the Ff ring to bring the chart into focus.

At this time, take care not to move the distance ring.

8 Repeat this operation four to seven times until the lens is in focus at both the telephoto and wide-angle positions.

9 Firmly tighten the Ff ring clamping screw.

ÁRefer to the Operating Instructions of the lens.