Black level (total pedestal) adjustment

When doing the adjustment

using the controller

When the AW-RP655 is connected:

1 Press the [IRIS] button several times to turn off its lamp.

Set the iris to the manual ([MANU]) mode.

2 Turn the [FOCUS/IRIS] dial to stop down the lens iris.

3 Press the [R/B GAIN/PED] button a number of times so that the “PEDESTAL TOTAL” item is displayed on the LCD panel.

4 Turn the jog dial (main) and adjust the black level to 5 IRE (0.035 V) or 7.5 IRE (0.050 V).

5 If necessary, adjust the iris automatically.

Press the [IRIS] button several times to turn on its lamp.

When the AW-RP555 is connected:

1 Press the [IRIS] button several times to turn off its lamp.

Set the iris to the manual ([MANU]) mode.

2 Turn the [LEVEL] dial of [IRIS] to stop down the lens iris.

3 The same operations as those in steps 3 to 8 of “When performing the operations using the accessory wireless remote control” can be performed following the operation procedure for “Basic menu operations” (page 42).

When the AW-RP400/AW-CB400 is connected: (The following operations are performed using the AWCB400.)

1 Press the [IRIS] button several times to turn off its lamp.

Set the iris to the manual ([MANU]) mode.

2 Turn the [IRIS] dial to stop down the lens iris.

3 Turn the [PED] dial and adjust it so that the pedestal level is set to 5 IRE (0.035 V) or 7.5 IRE (0.050 V).

4 If necessary, adjust the iris automatically.

Press the [IRIS] button several times to turn on its lamp.

Alternatively, the same operations as those in steps 3 to

8 of “When performing the operations using the accessory wireless remote control” can be performed following the operation procedure for “Basic menu operations” (pages 40 to 42).

36

Page 36
Image 36
Panasonic AW-HE100N operating instructions Press the Iris button several times to turn off its lamp