B. Feedback control

ii.Auto Fan Speed [Cooling, Dry]

š According to room temperature and setting temperature, indoor fan speed is determined automatically. š When set temperature is not achieved, the indoor fan will operate according to pattern below.

šWhen set temperature achieved, the indoor fan speed will be fixed. When thermostat off, the fan stop periodically. [Heating]

šAccording to indoor pipe temperature, automatic heating fan speed is determined as follows.

B. Feedback control

šImmediately after the fan motor started, feedback control is performed once every second.

šDuring fan motor on, if fan motor feedback ≥ 2550 rpm or < 50 rpm continue for 10 seconds, then fan motor error counter increase, fan motor is then stop and restart. If the fan motor counter becomes 7 times, then H19 - fan motor error is detected. Operation stops and cannot on back.

12.3 Outdoor Fan Motor Operation

šIt starts when compressor starts operation and it stops 30 seconds after compressor stops operation.

šDuring cooling operation, and outdoor ambient temperature is below 46.4°F (8°C), outdoor fan speed will be controlled according to outdoor piping temperature as following: