Panasonic CU-XE12PKUA manual 15.4.25 F97 Compressor Overheating, Malfunction Decision Conditions

Models: CU-XE12PKUA CU-XE9PKUA CS-XE9PKUA CS-XE12PKUA

1 102
Download 102 pages 16.71 Kb
Page 79
Image 79
15.4.25 F97 (Compressor Overheating)

15.4.25 F97 (Compressor Overheating)

Malfunction Decision Conditions

šDuring operation of cooling and heating, when compressor tank temperature data 233.6°F (112°C) is detected by the compressor tank temperature sensor.

Malfunction Caused

šFaulty compressor tank temperature sensor

š2/3 way valve closed

šRefrigerant shortage (refrigerant leakage)

šFaulty outdoor unit PCB

šFaulty compressor

Troubleshooting

79

Page 79
Image 79
Panasonic CU-XE12PKUA, CS-XE12PKUA 15.4.25 F97 Compressor Overheating, Malfunction Decision Conditions, Malfunction Caused