12.7 Powerful Mode Operation
When the powerful mode is selected, the internal setting temperature will shift lower up to 3.6°F (2°C) (for Cooling/Soft Dry) or higher up to 6.3°F (3.5°C) (for Heating) than remote control setting temperature for 20 minutes to achieve the setting temperature quickly.
12.8 Timer Control
There are 2 sets of ON and OFF timer available to turn the unit ON or OFF at different preset time.
If more than one timer had been set, the upcoming timer will be displayed and will activate in sequence.
12.8.1ON Timer Control
ON timer 1 and ON timer 2 can be set using remote control, the unit with timer set will start operate earlier than the setting time.
This is to provide a comfortable environment when reaching the set ON time.
60 minutes before the set time, indoor (at fan speed of
From the above judgment, the decided operation will start operate earlier than the set time as shown below.
12.8.2OFF Timer Control
OFF timer 1 and OFF timer 2 can be set using remote control, the unit with timer set will stop operate at set time.
12.9 Auto Restart Control
When the power supply is cut off during the operation of air conditioner, the compressor will
This type of control is not applicable during ON/OFF Timer setting.
This control can be omitted by open the circuit of JP1 at indoor unit printed circuit board.
12.10 Indication Panel
LED | POWER | TIMER | POWERFUL/QUIET | RFP | ECONAVI | AUTO COMFORT |
Color | Green | Orange | Orange | Green | Green | Green |
|
|
|
|
|
|
|
Light ON | Operation ON | Timer Setting ON | POWERFUL/QUIET | RFP ON | ECONAVI ON | AUTO COMFORT |
|
|
| Mode ON |
|
| ON |
Light OFF | Operation OFF | Timer Setting OFF | POWERFUL/QUIET | RFP OFF | ECONAVI OFF | AUTO COMFORT |
|
|
| Mode OFF |
|
| OFF |
Note:
If POWER LED is blinking, the possible operation of the unit are Hot Start, during Deice operation, operation mode judgment, or ON timer sampling.
If Timer LED is blinking, there is an abnormality operation occurs.
37