Panasonic CU-XE9PKUA manual ECONAVI and AUTO COMFORT Demo Mode, Human Activity Sensor Abnormality

Models: CU-XE12PKUA CU-XE9PKUA CS-XE9PKUA CS-XE12PKUA

1 102
Download 102 pages 16.71 Kb
Page 42
Image 42
12.12.1.10 ECONAVI and AUTO COMFORT Demo Mode

12.12.1.10 ECONAVI and AUTO COMFORT Demo Mode

šTo enable ECO DEMO mode:

šTo disable ECO Demo MODE:

o Transmit ECO Demo signal again.

12.12.1.11 Human Activity Sensor Abnormality

šAbnormality detection:

ƒConnector disconnection / Wire cut abnormality

o Sensor judge Hi level continuously for 25 seconds

ƒCircuit abnormality

o 70 seconds after power ON, if human activity sensor judge Lo level continuously for 25 seconds

šError Code judgment

ƒWhen abnormality happened, internal counter increase by 1 time.

ƒHuman activity sensor power OFF, retry after 5 seconds.

ƒWhen the human activity sensor maintains normal condition for 120 seconds, the counter reset or AC reset.

ƒWhen abnormality counter reached 4 times, H59 occurred – No TIMER indicator blinking.

šWhen error code happened, the unit is able to operate without AUTO COMFORT / ECONAVI.