15.4.17 H99 (Indoor Freeze Prevention Protection: Cooling or Soft Dry)

Error Code will not display (no Timer LED blinking) but store in EEPROM

Malfunction Decision Conditions

šFreeze prevention control takes place (when indoor pipe temperature is lower than 35.6°F (2°C))

Malfunction Caused

šAir short circuit at indoor unit

šClogged indoor unit air filter

šDust accumulation on the indoor unit heat exchanger

š2/3 way valve closed

šFaulty indoor unit fan motor

šRefrigerant shortage (refrigerant leakage)

šClogged expansion valve or strainer

šFaulty indoor pipe temperature sensor

šFaulty indoor unit PCB