17.2 Sensible Capacity Chart

17.2 Sensible Capacity Chart

šCU-XE9PKUA

208-230V

 

 

 

 

 

 

 

 

Outdoor Temperature

 

 

 

 

 

 

Indoor

 

86 °F (30 °C)

 

 

95 °F (35 °C)

 

104 °F (40 °C)

 

 

114.8 °F (46 °C)

 

wet bulb

TC

 

SHC

 

IP

TC

 

SHC

 

IP

TC

 

SHC

 

IP

TC

 

SHC

 

IP

62.6°F

2.53

 

1.92

 

0.49

2.36

 

1.84

 

0.53

2.20

 

1.77

 

0.57

2.00

 

1.68

 

0.61

(17.0 °C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

66.2°F

 

 

 

 

 

2.55

 

 

 

0.54

 

 

 

 

 

 

 

 

 

 

(19.0 °C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

67.1°F

2.78

 

2.01

 

0.50

2.60

 

1.93

 

0.54

2.41

 

1.86

 

0.58

2.20

 

1.77

 

0.63

(19.5 °C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

71.6°F

3.03

 

2.08

 

0.51

2.83

 

2.00

 

0.55

2.63

 

1.93

 

0.59

2.39

 

1.84

 

0.64

(22.0 °C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

šCU-XE12PKUA

208-230V

 

 

 

 

 

 

 

 

 

Outdoor Temperature

 

 

 

 

 

 

Indoor

 

86 °F (30 °C)

 

 

 

95 °F (35 °C)

 

104 °F (40 °C)

 

 

114.8 °F (46 °C)

 

wet bulb

TC

 

SHC

 

IP

 

TC

 

SHC

IP

TC

 

SHC

 

IP

TC

 

SHC

 

IP

62.6°F

3.33

 

2.53

 

0.73

 

3.11

 

2.42

0.79

2.90

 

2.33

 

0.84

2.63

 

2.21

 

0.91

(17.0 °C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

66.2°F

 

 

 

 

 

 

3.36

 

 

0.80

 

 

 

 

 

 

 

 

 

 

(19.0 °C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

67.1°F

3.66

 

2.65

 

0.75

 

3.42

 

2.54

0.80

3.18

 

2.45

 

0.86

2.89

 

2.33

 

0.93

(19.5 °C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

71.6°F

3.99

 

2.74

 

0.76

 

3.73

 

2.64

0.82

3.47

 

2.55

 

0.87

3.15

 

2.43

 

0.94

(22.0 °C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TC

- Total Cooling Capacity (kW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SHC - Sensible Heat Capacity (kW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IP

- Input Power (kW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor 80.6°F/66.2°F (27°C/19°C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 