Image 77
šDuring operation of cooling or soft dry, when outdoor unit heat exchanger high temperature data is detected by the outdoor unit heat exchanger thermistor.

15.4.23 F95 (Outdoor High Pressure Protection: Cooling or Soft Dry)

Malfunction Decision Conditions

šDuring operation of cooling or soft dry, when outdoor unit heat exchanger high temperature data is detected by the outdoor unit heat exchanger thermistor.

Malfunction Caused

šOutdoor heat exchanger temperature rise due to short-circuit of hot discharge air flow.

šOutdoor heat exchanger temperature rise due to defective of outdoor fan motor.

šOutdoor heat exchanger temperature rise due to defective outdoor heat exchanger thermistor.

šOutdoor heat exchanger temperature rise due to defective of outdoor unit PCB.

Troubleshooting