Panasonic CS-XE12PKUA manual Malfunction Decision Conditions, Malfunction Caused, Troubleshooting

Models: CU-XE12PKUA CU-XE9PKUA CS-XE9PKUA CS-XE12PKUA

1 102
Download 102 pages 16.71 Kb
Page 60
Image 60
šOperation stops due to Hall IC malfunction.

15.4.6H19 (Indoor Fan Motor – DC Motor Mechanism Locked)

Malfunction Decision Conditions

šThe rotation speed detected by the Hall IC during fan motor operation is used to determine abnormal fan motor (feedback of rotation > 2550rpm or < 50rpm)

Malfunction Caused

šOperation stops due to short circuit inside the fan motor winding.

šOperation stops due to breaking of wire inside the fan motor.

šOperation stops due to breaking of fan motor lead wires.

šOperation stops due to Hall IC malfunction.

šOperation error due to faulty indoor unit PCB.

Troubleshooting

60

Page 60
Image 60
Panasonic CS-XE12PKUA Malfunction Decision Conditions, Malfunction Caused, šOperation stops due to Hall IC malfunction