15.4.15 H97 (Outdoor Fan Motor – DC Motor Mechanism Locked)

Malfunction Decision Conditions

šThe rotation speed detected by the Hall IC during fan motor operation is used to determine abnormal fan motor.

Malfunction Caused

šOperation stops due to short circuit inside the fan motor winding.

šOperation stops due to breaking of wire inside the fan motor.

šOperation stops due to breaking of fan motor lead wires.

šOperation stops due to Hall IC malfunction.

šOperation error due to faulty outdoor unit PCB.

Troubleshooting