12.12.1.12 Human Activity Sensor Check Mode

12.12.1.12 Human Activity Sensor Check Mode

šTo enable human activity sensor abnormality check mode:

šDuring ECONAVI is ON, when CHECK signal received, if either sensors has abnormality, the 4 times abnormality counter is ignored, ECONAVI Indicator will blink immediately and error code is memorized.

šThe unit could operate without ECONAVI or AUTO COMFORT.

šThe ECONAVI indicator blinking could be cancelled by pressing ECONAVI button again.

šIf the human activity sensor has no abnormality, the CHECK process will end and continue with normal operation.